The effect of low-level laser 810 nm and light-emitting diode photobiomodulation (626 nm) on the stability of the implant and inflammatory markers interleukin-1 beta and prostaglandin E2, around implants

Background: One of the most common problems in edentulous patients is the low stability of lower dentures. The most effective method to overcome this problem is implant-supported overdentures. After placing an implant, for the process of osseointegration to be complete and successful, it is better t...

Full description

Saved in:
Bibliographic Details
Main Authors: Jafar Memarian (Author), Mohammad Ketabi (Author), Shahram Amini (Author)
Format: Book
Published: Wolters Kluwer Medknow Publications, 2018-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_dae5f4dbd4cc4f5584b9c224cfa0eaa2
042 |a dc 
100 1 0 |a Jafar Memarian  |e author 
700 1 0 |a Mohammad Ketabi  |e author 
700 1 0 |a Shahram Amini  |e author 
245 0 0 |a The effect of low-level laser 810 nm and light-emitting diode photobiomodulation (626 nm) on the stability of the implant and inflammatory markers interleukin-1 beta and prostaglandin E2, around implants 
260 |b Wolters Kluwer Medknow Publications,   |c 2018-01-01T00:00:00Z. 
500 |a 1735-3327 
500 |a 2008-0255 
500 |a 10.4103/1735-3327.237245 
520 |a Background: One of the most common problems in edentulous patients is the low stability of lower dentures. The most effective method to overcome this problem is implant-supported overdentures. After placing an implant, for the process of osseointegration to be complete and successful, it is better that patients do not use their denture for few months. This may be nonconvenient for patient because they are unable to speak and eat properly. The aim of this study was to evaluate the effect of low level laser (LLL) and light-emitting diode (LED) photobiomodulation on implant stability as well as their effect on interleukin-1 beta (IL-1β) and prostaglandin E2 (PGE2) biomarkers around implant in lower anterior region (over denture). Materials and Methods: In this clinical trial, 36 implants were placed in fully edentulous mandibles (12 people per person - three implants in areas of midline and canine). Each of the implants was randomly placed in one of three groups of laser, LED, and control. LLL (power of 50 mw and the amount of 20 J/cm2 for each implant) and LED with dose (20 mw/cm2) were irradiated on the day of surgery (zero), 3, 7, 10, and 14 days. The stability of implants was measured on the day of surgery and weeks 3, 4, and 8 after surgery with Periotest. The inflammatory biomarkers of IL-1β and PGE2 were also collected from gingival crevicular fluid around implants in 4 and 8 weeks. The collected data were analyzed by ANOVA statistical tests.pvalue<0.05 considered significant. Results: The amounts of Periotest significantly increased 3rd week after surgery in the control group (P < 0.001). However, the laser group and LED group were associated with minimal changes, which indicates lower stability of implant in 3rd week in control group but no changes in stability of test groups (laser and LED). Laser and LED had no effect on the level of IL-1β and PGE2 in 4 and 8 weeks. Conclusion: The use of LLL or LED has a positive effect on the stability of the implants 3 weeks after surgery. 
546 |a EN 
690 |a Dental implants 
690 |a interleukin 
690 |a laser 
690 |a overdentures 
690 |a prostaglandin E2 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Dental Research Journal, Vol 15, Iss 4, Pp 283-288 (2018) 
787 0 |n http://www.drjjournal.net/article.asp?issn=1735-3327;year=2018;volume=15;issue=4;spage=283;epage=288;aulast=Memarian 
787 0 |n https://doaj.org/toc/1735-3327 
787 0 |n https://doaj.org/toc/2008-0255 
856 4 1 |u https://doaj.org/article/dae5f4dbd4cc4f5584b9c224cfa0eaa2  |z Connect to this object online.