Retrospective Analysis of the Accuracy of High-Frequency Ultrasound for Pancreaticobiliary Maljunction in Pediatrics at a Single Center

ObjectiveTo determine the clinical value of high-frequency ultrasonography (US) in the evaluation and diagnosis of pancreaticobiliary maljunction (PBM) among children.MethodsThe clinical subjects consisted of 31 pediatric patients who were diagnosed with PBM from January 2015 to May 2021 in Fujian P...

Full description

Saved in:
Bibliographic Details
Main Authors: Qiuchen Xu (Author), Min Liu (Author), Qiumei Wu (Author), Wen Ling (Author), Shan Guo (Author)
Format: Book
Published: Frontiers Media S.A., 2022-04-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_db70e14b4d0b4bc6bee5b8d7bf7589da
042 |a dc 
100 1 0 |a Qiuchen Xu  |e author 
700 1 0 |a Min Liu  |e author 
700 1 0 |a Qiumei Wu  |e author 
700 1 0 |a Wen Ling  |e author 
700 1 0 |a Shan Guo  |e author 
245 0 0 |a Retrospective Analysis of the Accuracy of High-Frequency Ultrasound for Pancreaticobiliary Maljunction in Pediatrics at a Single Center 
260 |b Frontiers Media S.A.,   |c 2022-04-01T00:00:00Z. 
500 |a 2296-2360 
500 |a 10.3389/fped.2022.775378 
520 |a ObjectiveTo determine the clinical value of high-frequency ultrasonography (US) in the evaluation and diagnosis of pancreaticobiliary maljunction (PBM) among children.MethodsThe clinical subjects consisted of 31 pediatric patients who were diagnosed with PBM from January 2015 to May 2021 in Fujian Provincial Maternity and Children's Hospital. The primary outcomes included diagnosis accuracy, imaging characteristics of each type of PBM based on JSPBM, time length of operation, and cost of service. Secondary outcomes were the serum amylase and bilirubin levels.ResultsThe diagnostic accuracy of US was 90.3% and comparable to the other imaging methods-MRCP (82.6%), IOC (79.2%), and ERCP (100%), respectively. The time length of operation and direct cost were significantly lower than other imaging pathways. Stenotic type (A) is associated with a high internal diameter of CBD, and dilated channel type (C) presents increased internal diameter and length of CC as well as internal diameter of PD. There were higher levels of the serum bilirubin seen in type A and of serum amylase in type C compared with others.ConclusionHigh-frequency US is a safe, cost-effective, and non-invasive imaging tool for the diagnosis and evaluation of PBM in pediatrics. 
546 |a EN 
690 |a ultrasonography 
690 |a pancreaticobiliary maljunction (PBM) 
690 |a diagnostic imaging 
690 |a congenital biliary dilatation 
690 |a magnetic resonance cholangiopancreatography 
690 |a endoscopic retrograde cholangiopancreatography 
690 |a Pediatrics 
690 |a RJ1-570 
655 7 |a article  |2 local 
786 0 |n Frontiers in Pediatrics, Vol 10 (2022) 
787 0 |n https://www.frontiersin.org/articles/10.3389/fped.2022.775378/full 
787 0 |n https://doaj.org/toc/2296-2360 
856 4 1 |u https://doaj.org/article/db70e14b4d0b4bc6bee5b8d7bf7589da  |z Connect to this object online.