Assessment of the fracture strength of straight and pre-angled (17°) zircon implant abutments supported CADCAM zerconium restoration: An in(vitro study).

Aims :evaluate the effect of abutment angulation on fracture strength of pre-fabricated zircon implant abutment supported CADCAM zircon crown. Material and methods: Ten analog with 3.75×14mm were placed into resin blocks divided in to 2 groups: group A (n=5) parallel to long axis and group B (n= 5)...

Full description

Saved in:
Bibliographic Details
Main Authors: Zardasht N. Abdulghafoor (Author), Talal H. Al-salman (Author), Allaa Y. Daham (Author)
Format: Book
Published: University of Mosul, College of Dentistry, 2016-04-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_ddce4ce4325c4f9b8c6a01d3d0d43cd0
042 |a dc 
100 1 0 |a Zardasht N. Abdulghafoor  |e author 
700 1 0 |a Talal H. Al-salman  |e author 
700 1 0 |a  Allaa Y. Daham  |e author 
245 0 0 |a Assessment of the fracture strength of straight and pre-angled (17°) zircon implant abutments supported CADCAM zerconium restoration: An in(vitro study). 
260 |b University of Mosul, College of Dentistry,   |c 2016-04-01T00:00:00Z. 
500 |a 10.33899/rden.2016.160861 
500 |a 1812-1217 
500 |a 1998-0345 
520 |a Aims :evaluate the effect of abutment angulation on fracture strength of pre-fabricated zircon implant abutment supported CADCAM zircon crown. Material and methods: Ten analog with 3.75×14mm were placed into resin blocks divided in to 2 groups: group A (n=5) parallel to long axis and group B (n= 5) fixed at angulation (17°) to long axis. Then ten abutments were tightened to 25 N/cm2. Ten full anatomic zircon (CAD/CAM) crowns constructed as upper right central incisor: 5 on each group. After luting all crowns with dual cure resin-based luting, all samples passed to artificial aging using thermocycling machine, 500 cycles at (5 to 55 C°±2) degree. Then the load was applied by universal testing machine at 30 degree to the long axis until fracture occurred. Results: Statistical analysis showed that the implant abutment angulations significantly (p < 0.05) reduced the fracture resistance of zircon implant abutment. Conclusions: Within the limitation of this in vitro study it may be concluded that: the fracture strength of zircon implant abutment supported CADCAM zircon crown is significantly reduced in respect to the angulation fromstraight to angulated (17°) zircon abutment. 
546 |a AR 
546 |a EN 
690 |a zirconium 
690 |a zirconium dioxide 
690 |a implant abutment 
690 |a fracture resistance 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Al-Rafidain Dental Journal, Vol 16, Iss 1, Pp 77-83 (2016) 
787 0 |n https://rden.mosuljournals.com/pdf_160861_477c4ab659044d70307253a2d743a88c.html 
787 0 |n https://doaj.org/toc/1812-1217 
787 0 |n https://doaj.org/toc/1998-0345 
856 4 1 |u https://doaj.org/article/ddce4ce4325c4f9b8c6a01d3d0d43cd0  |z Connect to this object online.