Assessment of the fracture strength of straight and pre-angled (17°) zircon implant abutments supported CADCAM zerconium restoration: An in(vitro study).
Aims :evaluate the effect of abutment angulation on fracture strength of pre-fabricated zircon implant abutment supported CADCAM zircon crown. Material and methods: Ten analog with 3.75×14mm were placed into resin blocks divided in to 2 groups: group A (n=5) parallel to long axis and group B (n= 5)...
Saved in:
Main Authors: | , , |
---|---|
Format: | Book |
Published: |
University of Mosul, College of Dentistry,
2016-04-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_ddce4ce4325c4f9b8c6a01d3d0d43cd0 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Zardasht N. Abdulghafoor |e author |
700 | 1 | 0 | |a Talal H. Al-salman |e author |
700 | 1 | 0 | |a Allaa Y. Daham |e author |
245 | 0 | 0 | |a Assessment of the fracture strength of straight and pre-angled (17°) zircon implant abutments supported CADCAM zerconium restoration: An in(vitro study). |
260 | |b University of Mosul, College of Dentistry, |c 2016-04-01T00:00:00Z. | ||
500 | |a 10.33899/rden.2016.160861 | ||
500 | |a 1812-1217 | ||
500 | |a 1998-0345 | ||
520 | |a Aims :evaluate the effect of abutment angulation on fracture strength of pre-fabricated zircon implant abutment supported CADCAM zircon crown. Material and methods: Ten analog with 3.75×14mm were placed into resin blocks divided in to 2 groups: group A (n=5) parallel to long axis and group B (n= 5) fixed at angulation (17°) to long axis. Then ten abutments were tightened to 25 N/cm2. Ten full anatomic zircon (CAD/CAM) crowns constructed as upper right central incisor: 5 on each group. After luting all crowns with dual cure resin-based luting, all samples passed to artificial aging using thermocycling machine, 500 cycles at (5 to 55 C°±2) degree. Then the load was applied by universal testing machine at 30 degree to the long axis until fracture occurred. Results: Statistical analysis showed that the implant abutment angulations significantly (p < 0.05) reduced the fracture resistance of zircon implant abutment. Conclusions: Within the limitation of this in vitro study it may be concluded that: the fracture strength of zircon implant abutment supported CADCAM zircon crown is significantly reduced in respect to the angulation fromstraight to angulated (17°) zircon abutment. | ||
546 | |a AR | ||
546 | |a EN | ||
690 | |a zirconium | ||
690 | |a zirconium dioxide | ||
690 | |a implant abutment | ||
690 | |a fracture resistance | ||
690 | |a Dentistry | ||
690 | |a RK1-715 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n Al-Rafidain Dental Journal, Vol 16, Iss 1, Pp 77-83 (2016) | |
787 | 0 | |n https://rden.mosuljournals.com/pdf_160861_477c4ab659044d70307253a2d743a88c.html | |
787 | 0 | |n https://doaj.org/toc/1812-1217 | |
787 | 0 | |n https://doaj.org/toc/1998-0345 | |
856 | 4 | 1 | |u https://doaj.org/article/ddce4ce4325c4f9b8c6a01d3d0d43cd0 |z Connect to this object online. |