Brazilian questionnaire of competencies of oncology nurses: Construction and test of content validation

Objective: This study aimed to describe construction and content validation of the Brazilian Questionnaire of Competencies of Oncology Nurses. Methods: The methodological research was constructed based on the literature and observation in Brazilian hospitals searching to identify local evidence in t...

Full description

Saved in:
Bibliographic Details
Main Authors: Fabiana Cristina dos Santos (Author), Mary Elizabeth Riner (Author), Silvia Helena Henriques (Author)
Format: Book
Published: Elsevier, 2019-07-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_dded4870a4414a85b1ad8f3663a6c3db
042 |a dc 
100 1 0 |a Fabiana Cristina dos Santos  |e author 
700 1 0 |a Mary Elizabeth Riner  |e author 
700 1 0 |a Silvia Helena Henriques  |e author 
245 0 0 |a Brazilian questionnaire of competencies of oncology nurses: Construction and test of content validation 
260 |b Elsevier,   |c 2019-07-01T00:00:00Z. 
500 |a 2352-0132 
500 |a 10.1016/j.ijnss.2019.06.005 
520 |a Objective: This study aimed to describe construction and content validation of the Brazilian Questionnaire of Competencies of Oncology Nurses. Methods: The methodological research was constructed based on the literature and observation in Brazilian hospitals searching to identify local evidence in the nursing practice. After, the construction of the 30 items distributed in eight sub-dimensions of competencies, the instrument was tested the content validation by 7 experts and 61 oncology nurses. Item responses were analyzed through content validity index and Cronbach's α were used in this test pilot. Results: The content validity index of the scale was 0.90, and the content validity index of each item was 0.80-1.00. The mean of items varied between 4.98 (standard deviation = 0.13) and 4.70 (standard deviation = 0.53). The Cronbach's α of the instrument was 0.77. The Cronbach's α if each item was excluded ranged from 0.78 to 0.74, indicating consistency between items. Conclusion: The instrument is concise and clear, resulting in a valid content on test pilot in conducting a self-assessment the oncology nurses. It can be used to facilitate decision-making by identifying sub-dimensions that require attention in nursing education to improve patient care. Keywords: Clinical competence, Nurses, Oncology service, Hospital, Reliability, Validity 
546 |a EN 
690 |a Nursing 
690 |a RT1-120 
655 7 |a article  |2 local 
786 0 |n International Journal of Nursing Sciences, Vol 6, Iss 3, Pp 288-293 (2019) 
787 0 |n http://www.sciencedirect.com/science/article/pii/S235201321830173X 
787 0 |n https://doaj.org/toc/2352-0132 
856 4 1 |u https://doaj.org/article/dded4870a4414a85b1ad8f3663a6c3db  |z Connect to this object online.