Effect of Halogen Light Stimulation on Nonreactive Pattern of Nonstress Test (NST)

Background & Aim: The Non Stress Test (NST) is a main assessment tool for fetal wellbeing however, it has a high rate of false-positive results. External stimulation with halogen light has been recommended to aid in provoking fetal response, decreasing false-positive results and promoting the te...

Full description

Saved in:
Bibliographic Details
Main Authors: F Rahimikian (Author), M Modarres (Author), Sh Niromanesh (Author), A Mehran (Author), T Rahiminia (Author)
Format: Book
Published: Tehran University of Medical Sciences, 2011-07-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_e2b4c9d8c8d24726ae6df9e2dc4fd3f0
042 |a dc 
100 1 0 |a F Rahimikian  |e author 
700 1 0 |a M Modarres  |e author 
700 1 0 |a Sh Niromanesh  |e author 
700 1 0 |a A Mehran  |e author 
700 1 0 |a T Rahiminia  |e author 
245 0 0 |a Effect of Halogen Light Stimulation on Nonreactive Pattern of Nonstress Test (NST) 
260 |b Tehran University of Medical Sciences,   |c 2011-07-01T00:00:00Z. 
500 |a 1735-2215 
500 |a 2008-188X 
520 |a Background & Aim: The Non Stress Test (NST) is a main assessment tool for fetal wellbeing however, it has a high rate of false-positive results. External stimulation with halogen light has been recommended to aid in provoking fetal response, decreasing false-positive results and promoting the test. This study aimed to assess the effect of halogen light stimulation on nonreactive pattern of NST. Methods & Materials: From 850 women who underwent NSTs, 50 women with singleton and cephalic fetuses who had nonreactive NSTs were allocated to receive halogen light stimulation through a halogen light source of 1,000,000 candle power. The light was applied to the lower abdomen above symphysis pubis over fetal head for 10 seconds. Results were compared to BPP scores as a backup test. We used mean± SD, chi-square Test and Fisher&aposs Exact Test. The >α0.05 was considered as significant level. Results: Following stimulation, 68% of nonreactive results changed to reactive patterns. In half of the cases, first acceleration occurred in less than two minutes. Almost 90% of fetuses had reactive pattern within nine minutes. Conclusion: Halogen light stimulation decreased the incidence of non reactive tests and testing time. Halogen light stimulation is safe and efficient in fetal well being assessment. 
546 |a FA 
690 |a biophysical profile 
690 |a halogen light stimulation 
690 |a non stress test 
690 |a Nursing 
690 |a RT1-120 
655 7 |a article  |2 local 
786 0 |n حیات, Vol 17, Iss 2, Pp 12-21 (2011) 
787 0 |n http://hayat.tums.ac.ir/article-1-59-en.html 
787 0 |n https://doaj.org/toc/1735-2215 
787 0 |n https://doaj.org/toc/2008-188X 
856 4 1 |u https://doaj.org/article/e2b4c9d8c8d24726ae6df9e2dc4fd3f0  |z Connect to this object online.