Investigation into the Translucency of Tooth-Colored Restorative Materials

Objective: The aim of this study was to investigate the translucency of resin-modified glass-ionomer cements (RMGIC) and polyacid-modified composite resin (PCMR) over a period of one year. Materials and Methods: The study was done on three RMGIC (Fuji II LC, Photac-Fil Aplicap and Vitremer) and one...

Full description

Saved in:
Bibliographic Details
Main Authors: H. Torabzadeh (Author), R. Aminian (Author), A. Ghasemi (Author)
Format: Book
Published: Tehran University of Medical Sciences, 2009-09-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_e401438f5baf4ada852cc30b4a7f44d1
042 |a dc 
100 1 0 |a  H. Torabzadeh  |e author 
700 1 0 |a  R. Aminian  |e author 
700 1 0 |a  A. Ghasemi  |e author 
245 0 0 |a Investigation into the Translucency of Tooth-Colored Restorative Materials 
260 |b Tehran University of Medical Sciences,   |c 2009-09-01T00:00:00Z. 
500 |a 2676-296X 
520 |a Objective: The aim of this study was to investigate the translucency of resin-modified glass-ionomer cements (RMGIC) and polyacid-modified composite resin (PCMR) over a period of one year. Materials and Methods: The study was done on three RMGIC (Fuji II LC, Photac-Fil Aplicap and Vitremer) and one PCMR (Dyract). A conventional GIC (Fuji Cap II) and two composite resins (Tetric and Z 100) were used for comparison. Five discs approximately 5 mm in diameter and 1.5 mm thick were made from each material using a Perspex mould. The specimens were kept in distilled water at 37°C during the test period. The optical density/mm (inverse of translucency) of each material was measured using a special photometric set up after preparation and after one week, six months, and one year. Means and standard deviations were calculated and subjected to Two-way ANOVA, One- way ANOVA and Scheffe tests. Results: The results indicated that all of the materials, except Dyract, showed an increase of translucency over the test period. After one year, the conventional GIC was the least translucent material. Conclusion: The translucency of the resin-modified GICs and Dyract was equivalent to that of the composite resins Tetric and Z 100. 
546 |a EN 
690 |a Glass Ionomer Cements 
690 |a Fuji glass-ionomer lining cement 
690 |a Dyract 
690 |a Nuchal Translucency Measurement 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Frontiers in Dentistry, Vol 6, Iss 3 (2009) 
787 0 |n https://jdt.tums.ac.ir/index.php/jdt/article/view/193 
787 0 |n https://doaj.org/toc/2676-296X 
856 4 1 |u https://doaj.org/article/e401438f5baf4ada852cc30b4a7f44d1  |z Connect to this object online.