STUDY OF FORMALDEHYDE CONCENTRATION LEVELS IN THE AIR OF WORK PLACES
In this research, air sampling of workplaces was carried out by two methods (long - time and short - time). The mean formaldehyde concentration with long - time method in pathology labs, surgery and endoscopy sections were 0.96 0.25 and 0.13 ppm and with short - time method, 8 hours, was 3, 0.3 and...
Saved in:
Main Author: | |
---|---|
Format: | Book |
Published: |
Tehran University of Medical Sciences,
1997-12-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | In this research, air sampling of workplaces was carried out by two methods (long - time and short - time). The mean formaldehyde concentration with long - time method in pathology labs, surgery and endoscopy sections were 0.96 0.25 and 0.13 ppm and with short - time method, 8 hours, was 3, 0.3 and 0.2 ppm. The mean formaldehyde concentration in pathology labs was above the standard values (TLV - Ceiling = 0.3 ppm). In the long - time and short - time air sampling, the time of sampling was significantly effective on the concentration levels (P<0.05). Work practices and administrative procedures are important parts of a control system. If one is asked to perform a task in a certain manner to limit exposure to formaldehyde, it is extremely important that these procedures should be followed. |
---|---|