Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study

Background: The aim of the study was to evaluate the accuracy of iPex and Vdw gold apex locators in detecting simulated root perforations in curved canals in the presence of 3% sodium hypochlorite (NaOCl) and 2% chlorhexidine (CHX). Materials and Methods: In this comparative in vitro study Twenty ma...

Full description

Saved in:
Bibliographic Details
Main Authors: Monisha Parshotam Khatri (Author), Sheetal B Ghivari (Author), Madhu Pujar (Author), Reshma Faras (Author), Pallavi Gopeshetti (Author), Amulya Vanti (Author)
Format: Book
Published: Wolters Kluwer Medknow Publications, 2019-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_e637a458da7b40a4ba10c7cd7ea80bf4
042 |a dc 
100 1 0 |a Monisha Parshotam Khatri  |e author 
700 1 0 |a Sheetal B Ghivari  |e author 
700 1 0 |a Madhu Pujar  |e author 
700 1 0 |a Reshma Faras  |e author 
700 1 0 |a Pallavi Gopeshetti  |e author 
700 1 0 |a Amulya Vanti  |e author 
245 0 0 |a Accuracy of two electronic apex locators in locating root perforations in curved canals in dry and wet conditions: A comparative in vitro study 
260 |b Wolters Kluwer Medknow Publications,   |c 2019-01-01T00:00:00Z. 
500 |a 1735-3327 
500 |a 2008-0255 
500 |a 10.4103/1735-3327.270779 
520 |a Background: The aim of the study was to evaluate the accuracy of iPex and Vdw gold apex locators in detecting simulated root perforations in curved canals in the presence of 3% sodium hypochlorite (NaOCl) and 2% chlorhexidine (CHX). Materials and Methods: In this comparative in vitro study Twenty mandibular molars with curved mesial roots were selected and perforation was made in the danger zone 4 mm from the furcation area. The actual length of the perforation site was measured using stereomicroscope software using a #15 K file, following which the teeth were embedded in alginate molds. The perforation site was electronically measured using two apex locators, iPex and Vdw gold in dry condition and in the presence of 3% NaOCl and 2% CHX. The values obtained were compared using the Friedman and Wilcoxon signed-rank test with level of statistical significance set at P ≤ 0.05. Results: In dry condition, Vdw gold showed near accurate values, i.e., 0.25 mm from the manual value whereas iPex showed a significant difference (P < 0.05) of 0.76 mm from the manual value. In the presence of 3% NaOCl, both the apex locators showed a significant difference (P < 0.05) from the manual value with iPex showing a difference of 0.70 mm and Vdw gold showing a difference of 0.74 mm. The most accurate values were determined by both the apex locators in the presence of 2% CHX with iPex showing a deviation of 0.13 mm and Vdw gold showing a deviation of 0.39 mm from the manual. Conclusion: In dry condition, Vdw group showed better results than iPex in determining the length of the root perforation. In wet condition, in the presence of 2% CHX, both the apex locators accurately measured the perforation site, whereas in the presence of 3% NaOCl, both the apex locators showed a significant difference (P < 0.05) from the manual value in detecting the root perforation. 
546 |a EN 
690 |a curved 
690 |a root canal length 
690 |a root canal irrigants 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Dental Research Journal, Vol 16, Iss 6, Pp 407-412 (2019) 
787 0 |n http://www.drjjournal.net/article.asp?issn=1735-3327;year=2019;volume=16;issue=6;spage=407;epage=412;aulast=Khatri 
787 0 |n https://doaj.org/toc/1735-3327 
787 0 |n https://doaj.org/toc/2008-0255 
856 4 1 |u https://doaj.org/article/e637a458da7b40a4ba10c7cd7ea80bf4  |z Connect to this object online.