Sensibilización a bisfenol A y bisfenol F en trabajadores expuestos a resinas epoxi

Las aplicaciones de las diferentes resinas epoxi basadas en bisfenol A y F son extensas. Las resinas epoxi basadas en bisfenol F son más nuevas y resistentes que las de bisfenol A, y ambas son causa conocida de dermatitis de contacto alérgica. Se estudian 39 casos de sensibilización a resinas epo...

Full description

Saved in:
Bibliographic Details
Main Authors: L. Jiménez Bajo (Author), M. Fernández Guarino (Author), A. I. Del Pozo Pozo (Author), J. L. Martinez-Amo Gámez (Author), F. Heras Mendaza (Author), L. Conde-Salazar Gómez (Author)
Format: Book
Published: Escuela Nacional de Medicina del Trabajo, 2008-06-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_e7ccd4c53ee34fd1a736f63f1a4526d2
042 |a dc 
100 1 0 |a L. Jiménez Bajo  |e author 
700 1 0 |a M. Fernández Guarino  |e author 
700 1 0 |a A. I. Del Pozo Pozo  |e author 
700 1 0 |a J. L. Martinez-Amo Gámez  |e author 
700 1 0 |a F. Heras Mendaza  |e author 
700 1 0 |a L. Conde-Salazar Gómez  |e author 
245 0 0 |a Sensibilización a bisfenol A y bisfenol F en trabajadores expuestos a resinas epoxi 
260 |b Escuela Nacional de Medicina del Trabajo,   |c 2008-06-01T00:00:00Z. 
500 |a 0465-546X 
520 |a Las aplicaciones de las diferentes resinas epoxi basadas en bisfenol A y F son extensas. Las resinas epoxi basadas en bisfenol F son más nuevas y resistentes que las de bisfenol A, y ambas son causa conocida de dermatitis de contacto alérgica. Se estudian 39 casos de sensibilización a resinas epoxi en los últimos 5 años. Los resultados obtenidos son: prevalencia de sensibilización a resinas epoxi entre los pacientes estudiados del 2%, 27 varones y 8 mujeres, con una edad media de 42.77, un período de medio sensibilización de 23,8 meses. La sensibilización a bisfenol F desde que se incluye para las pruebas del parche en la batería de resinas epoxi es del 100% para los casos sensibilizados a la resina. La localización mayoritaria se dio en las manos, con una relevancia actual del 84%. Se recomendó un cambio de puesto en el trabajo al 46% de estos pacientes. El aumento de la sensibilización encontrada a bisfenol F puede explicarse por una sensibilización concomitante con bisfenol A, una declaración incorrecta de la composición de la resina o una reactividad cruzada de ambos.<br>The applications of epoxy resins based on bisphenol A and F are extensive. Epoxy resins based on bisphenol F are new and more resistant than epoxy resins based on bisphenol A. Both of them cause allergic contact dermatitis. In the last 5 years, we have studied 39 cases of sensitization to epoxy resin. The results of our study were these: the global prevalence of epoxy resin sensitization was 2%, 27 men and 8 women. The mean age was 42.77 years and the sensitization period was 23.8 months. The most frequent localization of the lesions were hands (84% of the patients). Since bisphenol F was included in epoxy resin battery for patch testing, a 100% of positives responses in patients sensitized to epoxy resin have been found. Sensitization to epoxy resins was a cause of change in workplace in 46% of cases in our series. There has been an increase in sensitization of bisphenol F that could be explained by a concomitant sensitization with bisphenol A, cross-reactivity between bisphenol Aand F or because an incorrect chemical compound information of the resin. 
546 |a EN 
546 |a ES 
690 |a Resina epoxi 
690 |a bisfenol A 
690 |a bisfenol F 
690 |a sensibilización concomitante 
690 |a reactividad cruzada 
690 |a Epoxy resin 
690 |a bisphenol F 
690 |a bisphenol A 
690 |a concomitant sensitization 
690 |a cross-reactivity 
690 |a Medicine 
690 |a R 
690 |a Internal medicine 
690 |a RC31-1245 
690 |a Industrial medicine. Industrial hygiene 
690 |a RC963-969 
655 7 |a article  |2 local 
786 0 |n Medicina y Seguridad del Trabajo, Vol 54, Iss 211, Pp 39-45 (2008) 
787 0 |n http://scielo.isciii.es/scielo.php?script=sci_arttext&pid=S0465-546X2008000200006 
787 0 |n https://doaj.org/toc/0465-546X 
856 4 1 |u https://doaj.org/article/e7ccd4c53ee34fd1a736f63f1a4526d2  |z Connect to this object online.