Non Invasive Measurement of Systolic Blood Pressure in Rats: A Simple Technique

Background: Non invasive, simple and economical instrument to measure blood pressure in r365-ats is important in cardiovascular research. Methods: Systolic blood pressure measuring instrument was fabricated using a tail cuff, photoplethysmograph, pressure transducer and PC with Biopac Software for r...

Full description

Saved in:
Bibliographic Details
Main Authors: Maria Pauline (Author), Sandhya T Avadhany (Author), K.N. Maruthy (Author)
Format: Book
Published: Al Ameen Medical College, 2011-10-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_e7df48b96c04402dbee18a68b0e87d5c
042 |a dc 
100 1 0 |a Maria Pauline  |e author 
700 1 0 |a Sandhya T Avadhany  |e author 
700 1 0 |a K.N. Maruthy  |e author 
245 0 0 |a Non Invasive Measurement of Systolic Blood Pressure in Rats: A Simple Technique 
260 |b Al Ameen Medical College,   |c 2011-10-01T00:00:00Z. 
500 |a 0974-1143 
520 |a Background: Non invasive, simple and economical instrument to measure blood pressure in r365-ats is important in cardiovascular research. Methods: Systolic blood pressure measuring instrument was fabricated using a tail cuff, photoplethysmograph, pressure transducer and PC with Biopac Software for recording. Tail cuff was used to occlude the tail artery, photoplethysmograph picked the blood flow pulses in the rat tail and the pressure transducer measured the cuff pressure and converted it into analog voltage. PPG signals were converted into voltage and amplified by the recording system with two channel amplifiers and in addition it also amplified analog voltage converted by the pressure transducer. Results: Calibration of the instrument entailed a simple Bland Altman's plot of pressure recorded as voltage changes against pressure changes in the mercury sphygmomanometer which is considered as gold standard. A regression value of r=0.9 and p=0.00 was obtained. A pilot study was done on ten female rats. Three blood pressure readings were taken on two occasions. Between - animal variation of BP was 123±7 (mean SD), CV=5.9% and within - animal variation of BP was 120 ±7, CV=5.5%. Conclusion: The tail cuff and PPG based technique to measure systolic blood pressure in rats is simple, economic, accurate and reliable. 
546 |a EN 
690 |a tail cuff 
690 |a blood pressure 
690 |a photoplethysmograph (PPG) 
690 |a Therapeutics. Pharmacology 
690 |a RM1-950 
690 |a Toxicology. Poisons 
690 |a RA1190-1270 
655 7 |a article  |2 local 
786 0 |n Al Ameen Journal of Medical Sciences, Vol 04, Iss 04, Pp 365-369 (2011) 
787 0 |n http://ajms.alameenmedical.org/article_Vol04-4-oct-dec-2011/AJMS.4.4.2011%20p%20365-369.pdf 
787 0 |n https://doaj.org/toc/0974-1143 
856 4 1 |u https://doaj.org/article/e7df48b96c04402dbee18a68b0e87d5c  |z Connect to this object online.