Stress analysis at bone-implant interface of single- and two-implant-retained mandibular overdenture using three-dimensional finite element analysis

Purpose: The purpose of this research was to compare stress distribution on the bone between single implant-retained and two-implant-retained mandibular overdentures using three-dimensional (3D) finite element analysis. Materials and Methods: Two 3D finite element models were designed. The first mod...

Full description

Saved in:
Bibliographic Details
Main Authors: Krishnakumar Lahoti (Author), Anup Pathrabe (Author), Jaykumar Gade (Author)
Format: Book
Published: Wolters Kluwer Medknow Publications, 2016-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_e9ea2376b166492f99b6bed1bba2f7a8
042 |a dc 
100 1 0 |a Krishnakumar Lahoti  |e author 
700 1 0 |a Anup Pathrabe  |e author 
700 1 0 |a Jaykumar Gade  |e author 
245 0 0 |a Stress analysis at bone-implant interface of single- and two-implant-retained mandibular overdenture using three-dimensional finite element analysis 
260 |b Wolters Kluwer Medknow Publications,   |c 2016-01-01T00:00:00Z. 
500 |a 0970-9290 
500 |a 1998-3603 
500 |a 10.4103/0970-9290.199587 
520 |a Purpose: The purpose of this research was to compare stress distribution on the bone between single implant-retained and two-implant-retained mandibular overdentures using three-dimensional (3D) finite element analysis. Materials and Methods: Two 3D finite element models were designed. The first model included single implant-supported mandibular overdenture placed in the midline of the mandible while the second model included two-implant-supported mandibular overdenture placed in the intra-foramen region, retained by ball attachment of the same diameter. The bone was modeled on the D2 bone depending on the classification given by Misch. A computed tomography scan of the mandible was used to model the bone by plotting the key points on the graph and generating the identical key points on the ANSYS Software (ANSYS, Inc., USA). The implant was modeled using appropriate dimensions as provided by the manufacturer. Stresses were calculated based on the von Mises criteria. Results: Stresses produced in the hard bone (HB) and soft bone (SB) were higher in single implant-retained mandibular overdenture while stresses produced around the denture as well as implant were higher in two-implant-retained mandibular overdenture. Conclusion: Within the limitations of the study, it had been seen that stresses produced were the highest on HB and SB in single implant-retained mandibular overdenture while stresses produced across the denture as well as implant were the highest in two-implant-retained mandibular overdenture. 
546 |a EN 
690 |a Ball attachment 
690 |a bone-implant interface 
690 |a finite element analysis 
690 |a mandibular overdenture 
690 |a von Mises stress 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Indian Journal of Dental Research, Vol 27, Iss 6, Pp 597-601 (2016) 
787 0 |n http://www.ijdr.in/article.asp?issn=0970-9290;year=2016;volume=27;issue=6;spage=597;epage=601;aulast=Lahoti 
787 0 |n https://doaj.org/toc/0970-9290 
787 0 |n https://doaj.org/toc/1998-3603 
856 4 1 |u https://doaj.org/article/e9ea2376b166492f99b6bed1bba2f7a8  |z Connect to this object online.