Molecular Ultrasound Monitoring of Early Artery Injury After Carotid Balloon Angioplasty

Cardiovascular intervention is a common treatment procedure for many cardiovascular diseases. But restenosis often occurs after these procedures, greatly discounting their long-term therapeutic effects. Early detection of endothelial denudation is helpful for the diagnosis and prevention of restenos...

Full description

Saved in:
Bibliographic Details
Main Authors: Xinhai Mo (Author), Fei Yan (Author), Bo Zhang (Author)
Format: Book
Published: Frontiers Media S.A., 2019-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_ecb07a93c25e4be8999320feaf1318a5
042 |a dc 
100 1 0 |a Xinhai Mo  |e author 
700 1 0 |a Fei Yan  |e author 
700 1 0 |a Bo Zhang  |e author 
245 0 0 |a Molecular Ultrasound Monitoring of Early Artery Injury After Carotid Balloon Angioplasty 
260 |b Frontiers Media S.A.,   |c 2019-01-01T00:00:00Z. 
500 |a 1663-9812 
500 |a 10.3389/fphar.2018.01569 
520 |a Cardiovascular intervention is a common treatment procedure for many cardiovascular diseases. But restenosis often occurs after these procedures, greatly discounting their long-term therapeutic effects. Early detection of endothelial denudation is helpful for the diagnosis and prevention of restenosis. Here, we fabricated targeted microbubbles by conjugating anti-collagen IV antibodies to the surface of biotinylated microbubbles (MBColIV) and applied them for ultrasound molecular imaging of endothelial injury at early stage. Our results showed that the MBColIV, with a typical multi-peak particle distribution, was successfully constructed, which was confirmed by Alexa Fluor® 555-labeled secondary antibody. Ex vivo adhesion of microbubbles revealed that MBColIV can effectively and specially bind to the surface of balloon-injured carotid artery. The in vivo animal experiments showed ultrasound molecular imaging signals from carotid artery-injured rats administrated with MBColIV were significantly higher than those administrated with isotype control microbubbles. Histological staining of the left carotid common artery revealed that collagen IV was obviously exposed after endothelium denudation in balloon-injured artery. In conclusion, our current study provides an effective approach to detect vascular injury at the early stage and a potential platform for image-guided therapy to vascular injury. 
546 |a EN 
690 |a ultrasound molecular imaging 
690 |a collagen IV 
690 |a artery injury 
690 |a restenosis 
690 |a targeted microbubbles 
690 |a Therapeutics. Pharmacology 
690 |a RM1-950 
655 7 |a article  |2 local 
786 0 |n Frontiers in Pharmacology, Vol 9 (2019) 
787 0 |n https://www.frontiersin.org/article/10.3389/fphar.2018.01569/full 
787 0 |n https://doaj.org/toc/1663-9812 
856 4 1 |u https://doaj.org/article/ecb07a93c25e4be8999320feaf1318a5  |z Connect to this object online.