Validity of Garmin Vívofit and Polar Loop for measuring daily step counts in free-living conditions in adults
Background: Wrist activity trackers (WATs) are becoming popular and widely used for the monitoring of physical activity. However, the validity of many WATs in measuring steps remains unknown. Objective: To determine the validity of the following WATs: Garmin Vívofit (Vívofit) and Polar Loop (Loop)...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Book |
Published: |
Palacký University Olomouc,
2016-09-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_ef0a2b8f575b4b5ea89a121320b48a5d | ||
042 | |a dc | ||
100 | 1 | 0 | |a Adam Šimůnek |e author |
700 | 1 | 0 | |a Jan Dygrýn |e author |
700 | 1 | 0 | |a Aleš Gába |e author |
700 | 1 | 0 | |a Lukáš Jakubec |e author |
700 | 1 | 0 | |a Jiri Stelzer |e author |
700 | 1 | 0 | |a František Chmelík |e author |
245 | 0 | 0 | |a Validity of Garmin Vívofit and Polar Loop for measuring daily step counts in free-living conditions in adults |
260 | |b Palacký University Olomouc, |c 2016-09-01T00:00:00Z. | ||
500 | |a 2336-4912 | ||
500 | |a 2336-4920 | ||
500 | |a 10.5507/ag.2016.014 | ||
520 | |a Background: Wrist activity trackers (WATs) are becoming popular and widely used for the monitoring of physical activity. However, the validity of many WATs in measuring steps remains unknown. Objective: To determine the validity of the following WATs: Garmin Vívofit (Vívofit) and Polar Loop (Loop), by comparing them with well-validated devices, Yamax Digiwalker SW-701 pedometer (Yamax) and hip-mounted ActiGraph GT3X+ accelerometer (ActiGraph), in healthy adults. Methods: In free-living conditions, adult volunteers (N = 20) aged 25 to 52 years wore two WATs (Vívofit and Loop) with Yamax and ActiGraph simultaneously over a 7 day period. The validity of Vívofit and Loop was assessed by comparing each device with the Yamax and ActiGraph, using a paired samples t-test, mean absolute percentage errors, intraclass correlation coefficients (ICC) and Bland-Altman plots. Results: The differences between average steps per day were significant for all devices, except the difference between Vívofit and Yamax (p = .06; d = 0.2). Compared with Yamax and ActiGraph, the mean absolute percentage errors of Vívofit were -4.0% and 12.5%, respectively. For Loop the mean absolute percentage error was 8.9% compared with Yamax and 28.0% compared with ActiGraph. Vívofit showed a very strong correlation with both Yamax and ActiGraph (ICC = .89). Loop showed a very strong correlation with Yamax (ICC = .89) and a strong correlation with ActiGraph (ICC = .70). Conclusions: Vívofit showed higher validity than Loop in measuring daily step counts in free-living conditions. Loop appears to overestimate the daily number of steps in individuals who take more steps during a day. | ||
546 | |a EN | ||
690 | |a physical activity | ||
690 | |a pedometer | ||
690 | |a accelerometer | ||
690 | |a activity tracker | ||
690 | |a validity | ||
690 | |a measurement | ||
690 | |a Sports medicine | ||
690 | |a RC1200-1245 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n Acta Gymnica, Vol 46, Iss 3, Pp 129-135 (2016) | |
787 | 0 | |n http://gymnica.upol.cz/artkey/gym-201603-0004_Validity_of_Garmin_Vivofit_and_Polar_Loop_for_measuring_daily_step_counts_in_free-living_conditions_in_adults.php | |
787 | 0 | |n https://doaj.org/toc/2336-4912 | |
787 | 0 | |n https://doaj.org/toc/2336-4920 | |
856 | 4 | 1 | |u https://doaj.org/article/ef0a2b8f575b4b5ea89a121320b48a5d |z Connect to this object online. |