Estimating a Sleep Apnea Hypopnea Index Based on the ERB Correlation Dimension of Snore Sounds

This paper proposes a new perspective of analyzing non-linear acoustic characteristics of the snore sounds. According to the ERB (Equivalent Rectangular Bandwidth) scale used in psychoacoustics, the ERB correlation dimension (ECD) of the snore sound was computed to feature different severity levels...

Full description

Saved in:
Bibliographic Details
Main Authors: Limin Hou (Author), Qiang Pan (Author), Hongliang Yi (Author), Dan Shi (Author), Xiaoyu Shi (Author), Shankai Yin (Author)
Format: Book
Published: Frontiers Media S.A., 2021-02-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_f034483c115e434c9cde9ec4af7a4e5b
042 |a dc 
100 1 0 |a Limin Hou  |e author 
700 1 0 |a Qiang Pan  |e author 
700 1 0 |a Hongliang Yi  |e author 
700 1 0 |a Dan Shi  |e author 
700 1 0 |a Xiaoyu Shi  |e author 
700 1 0 |a Shankai Yin  |e author 
245 0 0 |a Estimating a Sleep Apnea Hypopnea Index Based on the ERB Correlation Dimension of Snore Sounds 
260 |b Frontiers Media S.A.,   |c 2021-02-01T00:00:00Z. 
500 |a 2673-253X 
500 |a 10.3389/fdgth.2020.613725 
520 |a This paper proposes a new perspective of analyzing non-linear acoustic characteristics of the snore sounds. According to the ERB (Equivalent Rectangular Bandwidth) scale used in psychoacoustics, the ERB correlation dimension (ECD) of the snore sound was computed to feature different severity levels of sleep apnea hypopnea syndrome (SAHS). For the training group of 93 subjects, snore episodes were manually segmented and the ECD parameters of the snores were extracted, which established the gaussian mixture models (GMM). The nocturnal snore sound of the testing group of another 120 subjects was tested to detect SAHS snores, thus estimating the apnea hypopnea index (AHI), which is called AHIECD. Compared to the AHIPSG value of the gold standard polysomnography (PSG) diagnosis, the estimated AHIECD achieved an accuracy of 87.5% in diagnosis the SAHS severity levels. The results suggest that the ECD vectors can be effective parameters for screening SAHS. 
546 |a EN 
690 |a apnea hypopnea index 
690 |a correlation dimension 
690 |a non-linear acoustic characteristics 
690 |a snore sound 
690 |a sleep apnea hypopnea syndrome 
690 |a Medicine 
690 |a R 
690 |a Public aspects of medicine 
690 |a RA1-1270 
690 |a Electronic computers. Computer science 
690 |a QA75.5-76.95 
655 7 |a article  |2 local 
786 0 |n Frontiers in Digital Health, Vol 2 (2021) 
787 0 |n https://www.frontiersin.org/articles/10.3389/fdgth.2020.613725/full 
787 0 |n https://doaj.org/toc/2673-253X 
856 4 1 |u https://doaj.org/article/f034483c115e434c9cde9ec4af7a4e5b  |z Connect to this object online.