Electrochemical sensor based on multi-walled carbon nanotubes and 4-(((4-mercaptophenyl)imino)methyl) benzene-1,2-diol for simultaneous determination of epinephrine in the presence of acetaminophen

A carbon paste electrode modified with 4-(((4-mercaptophenyl)imino)methyl)benzene-1,2-diol (MIB) and multi-walled carbon nanotubes MIB /CNT/CPE) was prepared for determination of epinefrine (EP) in the presence of acetaminophen (AC). Cyclic voltammetry, chronoamperometry and differential pulse voltam...

Full description

Saved in:
Bibliographic Details
Main Authors: Roghayyeh Aghaei (Author), Mohammad Mazloum-Ardakani (Author), Mohammad Abdollahi-Alibeik (Author), Ali Moaddeli (Author)
Format: Book
Published: Shiraz University of Medical Sciences, 2018-09-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_f30eab6a10c24509a50cbc18b4aa277f
042 |a dc 
100 1 0 |a Roghayyeh Aghaei  |e author 
700 1 0 |a Mohammad Mazloum-Ardakani  |e author 
700 1 0 |a Mohammad Abdollahi-Alibeik  |e author 
700 1 0 |a Ali Moaddeli  |e author 
245 0 0 |a Electrochemical sensor based on multi-walled carbon nanotubes and 4-(((4-mercaptophenyl)imino)methyl) benzene-1,2-diol for simultaneous determination of epinephrine in the presence of acetaminophen 
260 |b Shiraz University of Medical Sciences,   |c 2018-09-01T00:00:00Z. 
500 |a 2423-5652 
520 |a A carbon paste electrode modified with 4-(((4-mercaptophenyl)imino)methyl)benzene-1,2-diol (MIB) and multi-walled carbon nanotubes MIB /CNT/CPE) was prepared for determination of epinefrine (EP) in the presence of acetaminophen (AC). Cyclic voltammetry, chronoamperometry and differential pulse voltammetry (DPV) techniques were used to investigate the modified electrode for the electrocatalytic oxidation of (EP) and (AC) in aqueous solutions. The separation of the oxidation peak potential for EP- AC was 200 mV. Under the optimum conditions, the calibration curve for EP was obtained in the range of 1.0 to 25.0 µM and 25.0 to 500.0 µM. The diffusion coefficient for the oxidation of EP at the surface of modified electrode was calculated as 5.76×10-5 cm2s-1. 
546 |a EN 
690 |a Pharmacy and materia medica 
690 |a RS1-441 
655 7 |a article  |2 local 
786 0 |n Trends in Pharmaceutical Sciences, Vol 4, Iss 3, Pp 139-148 (2018) 
787 0 |n http://tips.sums.ac.ir/article_42260_dbc52bbf52dbf81060bd6a71c19d9e92.pdf 
787 0 |n https://doaj.org/toc/2423-5652 
856 4 1 |u https://doaj.org/article/f30eab6a10c24509a50cbc18b4aa277f  |z Connect to this object online.