Analysis of bone quality formation in sinus lifts with immediate implants

Abstract Sinus lift surgeries are part of the daily practice of dentists. This study evaluates the long-term structure of the bone placed in sinus lifts through the fractal dimension. We conducted a retrospective study on a sample of 35 patients with 51 sinus lifts performed using a lateral window a...

Full description

Saved in:
Bibliographic Details
Main Authors: Sofía Soler-Alcaraz (Author), Yolanda Guerrero-Sánchez (Author), Osmundo Gilbel Del Águila (Author), Juan Carlos Bernabeu-Mira (Author), Fabio Camacho-Alonso (Author)
Format: Book
Published: BMC, 2024-10-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_f42c1bbe876f4e90a9f47c2295a67d89
042 |a dc 
100 1 0 |a Sofía Soler-Alcaraz  |e author 
700 1 0 |a Yolanda Guerrero-Sánchez  |e author 
700 1 0 |a Osmundo Gilbel Del Águila  |e author 
700 1 0 |a Juan Carlos Bernabeu-Mira  |e author 
700 1 0 |a Fabio Camacho-Alonso  |e author 
245 0 0 |a Analysis of bone quality formation in sinus lifts with immediate implants 
260 |b BMC,   |c 2024-10-01T00:00:00Z. 
500 |a 10.1186/s12903-024-04953-9 
500 |a 1472-6831 
520 |a Abstract Sinus lift surgeries are part of the daily practice of dentists. This study evaluates the long-term structure of the bone placed in sinus lifts through the fractal dimension. We conducted a retrospective study on a sample of 35 patients with 51 sinus lifts performed using a lateral window approach and filling material placement. We radiologically analyzed the graft bone to observe its evolution up to one and a half years after the surgical procedure. The obtained results were the average area of the sinuses analyzed was 1401.96 mm2, with a mean area occupied by the filling material of 297.75 mm2. Significant differences are observed when comparing the fractal dimension values obtained on the initial day and one year after prosthesis loading. Similarly, when comparing the values of the area occupied by the biomaterial at the start day and one year after prosthesis loading, significant differences are also obtained (p-value < 0.001). In conclusion, the filling material used in the lateral window sinus lift procedure undergoes significant resorption and shows changes in the fractal dimension. 
546 |a EN 
690 |a Maxillary sinus 
690 |a Fractal dimension 
690 |a Filling material 
690 |a Lateral window 
690 |a Sinus lift 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n BMC Oral Health, Vol 24, Iss 1, Pp 1-6 (2024) 
787 0 |n https://doi.org/10.1186/s12903-024-04953-9 
787 0 |n https://doaj.org/toc/1472-6831 
856 4 1 |u https://doaj.org/article/f42c1bbe876f4e90a9f47c2295a67d89  |z Connect to this object online.