Comparative evaluation of displacement and stress distribution pattern during mandibular arch distalization with extra and inter-radicular mini-implants: a three-dimensional finite element study

ABSTRACT Objective: To compare the initial stress distribution and displacement on mandibular dentition using extra and inter-radicular mini-implants for arch distalization, by means of finite element analysis. Methods: For this study, two finite element models of the mandible were designed. The mod...

Full description

Saved in:
Bibliographic Details
Main Authors: Amit MAHESHWARI (Author), Dhruv Nilesh CHAWDA (Author), Ashish KUSHWAH (Author), Rajesh Kumar AGARWAL (Author), Amesh Kr GOLWARA (Author), Prateek Bhushan DIXIT (Author)
Format: Book
Published: Dental Press Editora, 2023-05-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_f45143bbed9f4af9b0b522a81f1162b2
042 |a dc 
100 1 0 |a Amit MAHESHWARI  |e author 
700 1 0 |a Dhruv Nilesh CHAWDA  |e author 
700 1 0 |a Ashish KUSHWAH  |e author 
700 1 0 |a Rajesh Kumar AGARWAL  |e author 
700 1 0 |a Amesh Kr GOLWARA  |e author 
700 1 0 |a Prateek Bhushan DIXIT  |e author 
245 0 0 |a Comparative evaluation of displacement and stress distribution pattern during mandibular arch distalization with extra and inter-radicular mini-implants: a three-dimensional finite element study 
260 |b Dental Press Editora,   |c 2023-05-01T00:00:00Z. 
500 |a 2177-6709 
500 |a 10.1590/2177-6709.28.2.e2321373.oar 
520 |a ABSTRACT Objective: To compare the initial stress distribution and displacement on mandibular dentition using extra and inter-radicular mini-implants for arch distalization, by means of finite element analysis. Methods: For this study, two finite element models of the mandible were designed. The models consisted of periodontal ligament (PDL) and alveolar bone of all teeth until second molars. In the Case 1, bilateral extra-radicular buccal-shelf stainless steel mini-implants (10.0-mm length; 2.0-mm diameter) were placed between first and second permanent molars. In the Case 2, bilateral inter-radicular stainless steel mini-implants (10.0-mm length; 1.5-mm diameter) were placed between second premolar and first permanent molar. Power hook was attached between canine and first premolar at a fixed height of 8mm. In the two cases, 200g of distalization force was applied. ANSYS v. 12.1 software was used to analyze and compare von Mises stress and displacement in the mandibular dentition, PDL and bone. Results: Higher stresses were observed in mandibular dentition with the inter-radicular implant system. The amount of von Mises stress was higher for cortical bone (85.66MPa) and cancellous bone (3.64MPa) in Case 2, in comparison to cortical bone (41.93MPa) and cancellous bone (3.43MPa) in Case 1. The amount of arch distalization was higher for mandible in Case 1 (0.028mm), in comparison to Case 2 (0.026mm). Conclusion: Both systems were clinically safe, but extra-radicular implants showed more effective and controlled distalization pattern, in comparison to inter-radicular implants, in Class III malocclusion treatment. 
546 |a EN 
546 |a PT 
690 |a Arch distalization 
690 |a Buccal shelf implant 
690 |a Extra-radicular 
690 |a Inter-radicular 
690 |a Finite element method 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Dental Press Journal of Orthodontics, Vol 28, Iss 2 (2023) 
787 0 |n http://www.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512023000200304&lng=en&tlng=en 
787 0 |n http://www.scielo.br/pdf/dpjo/v28n2/2177-6709-dpjo-28-02-e2321373.pdf 
787 0 |n https://doaj.org/toc/2177-6709 
856 4 1 |u https://doaj.org/article/f45143bbed9f4af9b0b522a81f1162b2  |z Connect to this object online.