Bacterial contamination in the different parts of household air conditioners: a comprehensive evaluation from Chengdu, Southwest China

IntroductionAir flow driven by air-conditioner has a significant impact on the indoor environment, however, the bacterial contamination conditions in the different parts of air-conditioners have not been fully elucidated.MethodsIn this study, we assessed the bacterial pollution in the four parts, in...

Full beskrivning

Sparad:
Bibliografiska uppgifter
Huvudupphovsmän: Donglei Sun (Författare, medförfattare), Li Tang (Författare, medförfattare), Keyan Long (Författare, medförfattare), Weilian Sun (Författare, medförfattare), Zunzhen Zhang (Författare, medförfattare)
Materialtyp: Bok
Publicerad: Frontiers Media S.A., 2024-08-01T00:00:00Z.
Ämnen:
Länkar:Connect to this object online.
Taggar: Lägg till en tagg
Inga taggar, Lägg till första taggen!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_f657df1abc404f4bb1fe2e3fbe6d14a1
042 |a dc 
100 1 0 |a Donglei Sun  |e author 
700 1 0 |a Li Tang  |e author 
700 1 0 |a Keyan Long  |e author 
700 1 0 |a Weilian Sun  |e author 
700 1 0 |a Zunzhen Zhang  |e author 
245 0 0 |a Bacterial contamination in the different parts of household air conditioners: a comprehensive evaluation from Chengdu, Southwest China 
260 |b Frontiers Media S.A.,   |c 2024-08-01T00:00:00Z. 
500 |a 2296-2565 
500 |a 10.3389/fpubh.2024.1429626 
520 |a IntroductionAir flow driven by air-conditioner has a significant impact on the indoor environment, however, the bacterial contamination conditions in the different parts of air-conditioners have not been fully elucidated.MethodsIn this study, we assessed the bacterial pollution in the four parts, including air outlet, filter net, cooling fin and water sink, of ten household air-conditioners quantitatively and qualitatively from Chengdu, southwestern China.ResultsThe microbial cultivation results showed the large total bacterial counts of 5042.0, 9127.6, 6595.1, and 12296.2 CFU/cm2 in air outlet, filter net, cooling fin, and water sink. Furthermore, the sequencing data showed that these four parts displayed different bacterial characteristics. At the level of genus, Caproiciproducens and Acidipropionibacterium were predominant in air outlet. Bacillus, Acinetobacter, Paracoccus, and Corynebacterium were detected as the characteristic bacteria in filter net. For cooling fin, Rhodococcus, Achromobacter, and Nocardioides were the dominant bacteria. The genera of Methylobacterium-Methylorubrum, Brevibacterium, Stenotrophomonas, and Psychrobacter were identified as the bioindicators in water sink. The bioinformatic analysis on the sequencing data illustrated that the bacteria from air-conditioners were associated with metabolic disturbance.DiscussionThis study reveals the distinct bacterial compositions in the different parts of air-conditioner, and provides new clues for the non-negligible bacterial pollution in this common appliance from Chinese households. 
546 |a EN 
690 |a microbial contamination 
690 |a household air-conditioner 
690 |a indoor environment 
690 |a bacterium 
690 |a 16S ribosomal RNA gene sequencing 
690 |a Public aspects of medicine 
690 |a RA1-1270 
655 7 |a article  |2 local 
786 0 |n Frontiers in Public Health, Vol 12 (2024) 
787 0 |n https://www.frontiersin.org/articles/10.3389/fpubh.2024.1429626/full 
787 0 |n https://doaj.org/toc/2296-2565 
856 4 1 |u https://doaj.org/article/f657df1abc404f4bb1fe2e3fbe6d14a1  |z Connect to this object online.