Validity and Reliability of Wearable Technology Devices during Simulated Pickleball Game Play

Pickleball is a popular sport. Also popular is wearable technology usage. Because the validity and reliability of wearable technology during pickleball is unknown, the purpose of this research was to evaluate the ability of common devices to return heart rate and estimated energy expenditure during...

Full description

Saved in:
Bibliographic Details
Main Authors: James W. Navalta (Author), Bryson Carrier (Author), Matahn Blank (Author), Setareh Zarei (Author), Dustin W. Davis (Author), Micah Craig (Author), Olivia R. Perez (Author), Jacob Baca (Author), Thea S. Sweder (Author), Tashari Carballo (Author), Jamaal Bovell (Author)
Format: Book
Published: MDPI AG, 2024-08-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_f85b34c63caa4b5384bc2db4e8a4ef55
042 |a dc 
100 1 0 |a James W. Navalta  |e author 
700 1 0 |a Bryson Carrier  |e author 
700 1 0 |a Matahn Blank  |e author 
700 1 0 |a Setareh Zarei  |e author 
700 1 0 |a Dustin W. Davis  |e author 
700 1 0 |a Micah Craig  |e author 
700 1 0 |a Olivia R. Perez  |e author 
700 1 0 |a Jacob Baca  |e author 
700 1 0 |a Thea S. Sweder  |e author 
700 1 0 |a Tashari Carballo  |e author 
700 1 0 |a Jamaal Bovell  |e author 
245 0 0 |a Validity and Reliability of Wearable Technology Devices during Simulated Pickleball Game Play 
260 |b MDPI AG,   |c 2024-08-01T00:00:00Z. 
500 |a 10.3390/sports12090234 
500 |a 2075-4663 
520 |a Pickleball is a popular sport. Also popular is wearable technology usage. Because the validity and reliability of wearable technology during pickleball is unknown, the purpose of this research was to evaluate the ability of common devices to return heart rate and estimated energy expenditure during pickleball activity. Twenty adult participants were outfitted with a portable metabolic unit and heart rate monitor (criterion measures). Experimental devices were a Garmin Instinct, Polar Vantage M2, Polar OH1, and Polar Verity Sense. Participants played simulated pickleball for 10 min. Validity measures included mean absolute percent error (MAPE) and Lin's Concordance Correlation Coefficient (CCC), whereas reliability measures included coefficient of variation (CV) and intraclass correlation coefficient (ICC). The heart rate returned lower than 10% MAPE across all devices (Instinct = 5.73-6.32%, Verity Sense = 2.92-2.97%, OH1 = 3.39-3.45%) and greater than 0.85 CCC (Instinct = 0.85-0.88, Verity Sense = 0.96-0.96, OH1 = 0.93-0.94). The CV was below 10% (Instinct = 9.30%, Verity Sense = 2.68%, OH1 = 5.01%), and ICC was above 0.7 (Instinct = 0.77, Verity Sense = 0.98, OH1 = 0.91). The energy expenditure MAPE was greater than 10% (Instinct = 27.67-28.08%, Vantage M2 = 18.87-23.38%) with CCC lower than 0.7 (Instinct = 0.47-0.49, Vantage M2 = 0.62-0.63). Reliability thresholds were met in the Vantage M2 (CV = 6%, ICC = 0.98) but not in the Instinct (CV = 15%, ICC = 0.86). The Instinct was neither valid nor reliable for estimated energy expenditure, while the Polar Vantage M2 was reliable but not valid. All devices returned valid and reliable heart rates during pickleball. 
546 |a EN 
690 |a accuracy 
690 |a consistency 
690 |a paddle sport 
690 |a Garmin Instinct 
690 |a Polar Vantage M2 
690 |a Sports 
690 |a GV557-1198.995 
655 7 |a article  |2 local 
786 0 |n Sports, Vol 12, Iss 9, p 234 (2024) 
787 0 |n https://www.mdpi.com/2075-4663/12/9/234 
787 0 |n https://doaj.org/toc/2075-4663 
856 4 1 |u https://doaj.org/article/f85b34c63caa4b5384bc2db4e8a4ef55  |z Connect to this object online.