Development and Testing of an Algorithm to Prevent Medical Device-Related Pressure Injuries

We developed and tested the effectiveness of an algorithm to prevent medical device-related pressure injuries in intensive care unit patients. It was developed in four stages: literature review and analysis of medical records; preliminary algorithm development; validation of the preliminary algorith...

Full description

Saved in:
Bibliographic Details
Main Authors: Yeong-Mi Seong RN, MS (Author), Hyejin Lee RN, PhD (Author), Ji Min Seo RN, PhD (Author)
Format: Book
Published: SAGE Publishing, 2021-10-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_f96d9ad252de41ab9f7606c80f12b0e7
042 |a dc 
100 1 0 |a Yeong-Mi Seong RN, MS  |e author 
700 1 0 |a Hyejin Lee RN, PhD  |e author 
700 1 0 |a Ji Min Seo RN, PhD  |e author 
245 0 0 |a Development and Testing of an Algorithm to Prevent Medical Device-Related Pressure Injuries 
260 |b SAGE Publishing,   |c 2021-10-01T00:00:00Z. 
500 |a 0046-9580 
500 |a 1945-7243 
500 |a 10.1177/00469580211050219 
520 |a We developed and tested the effectiveness of an algorithm to prevent medical device-related pressure injuries in intensive care unit patients. It was developed in four stages: literature review and analysis of medical records; preliminary algorithm development; validation of the preliminary algorithm by experts in two rounds; and practical feasibility verification of the revised algorithm by 109 intensive care unit nurses. To verify the algorithm's effectiveness, we compared the incidence of medical device-related pressure injuries between 324 patients without algorithm application (control group) and 312 patients with algorithm application (experimental group). The outcomes were skin inspection of the medical device attachment, pressure injury evaluation, and implementation of pressure injury-preventive nursing care, based on the medical device type. The incidence rates were 1.46 per 100 devices (control group) and 1.19 per 100 devices (experimental group). Since there was no homogeneity in the previous score of the Braden scale in the experimental and control groups, the results regarding the incidence of pressure damage after applying the algorithm should be interpreted with care. Applying this algorithm was a safe intervention that helped prevent medical device-related pressure injuries in this population. 
546 |a EN 
690 |a Public aspects of medicine 
690 |a RA1-1270 
655 7 |a article  |2 local 
786 0 |n Inquiry: The Journal of Health Care Organization, Provision, and Financing, Vol 58 (2021) 
787 0 |n https://doi.org/10.1177/00469580211050219 
787 0 |n https://doaj.org/toc/0046-9580 
787 0 |n https://doaj.org/toc/1945-7243 
856 4 1 |u https://doaj.org/article/f96d9ad252de41ab9f7606c80f12b0e7  |z Connect to this object online.