Impact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites
Objective: To investigate the effect of light-curing distance on the effectiveness of cure (EC) of bulk-fill resin-based composites (RBCs). Materials and methods: Two bulk-fill RBCs (a Tetric N-Ceram Bulk Fill (TN) and a Filtek Bulk Fill (FK)) are evaluated. Specimens (4 mm high) are cured for 20 s...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Book |
Published: |
Elsevier,
2021-12-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_fa3e8e94243a4ad88a2e002da2a9a8c7 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Rana Abdelbaset Diab |e author |
700 | 1 | 0 | |a Adrian Ujin Yap |e author |
700 | 1 | 0 | |a Maria Angela Garcia Gonzalez |e author |
700 | 1 | 0 | |a Noor Azlin Yahya |e author |
245 | 0 | 0 | |a Impact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites |
260 | |b Elsevier, |c 2021-12-01T00:00:00Z. | ||
500 | |a 1013-9052 | ||
500 | |a 10.1016/j.sdentj.2021.01.003 | ||
520 | |a Objective: To investigate the effect of light-curing distance on the effectiveness of cure (EC) of bulk-fill resin-based composites (RBCs). Materials and methods: Two bulk-fill RBCs (a Tetric N-Ceram Bulk Fill (TN) and a Filtek Bulk Fill (FK)) are evaluated. Specimens (4 mm high) are cured for 20 s at different distances (0 mm (D0), 2 mm (D2), 4 mm (D4), 6 mm (D6) and 8 mm (D8)) and stored for 24 h in 100% relative humidity at 37 °C. The top and bottom surface hardness (SH) (n = 12) are assessed using a Knoop microhardness tester and the EC is calculated. The EC is characterized by the hardness ratio (HR) (mean bottom: top SH). An HR of 0.8 is used as the benchmark for an effective/adequate cure. Data are analyzed using one-way analysis of variance and Tukey's post hoc test (α = 0.05). Correlations between the top and bottom surfaces are examined using the Pearson correlation (α = 0.05). Results: For the TN, the HR at D8 is significantly lower than all other light-curing distances, while for the FK, it is significantly lower than D0 only. Conclusion: The effect of light-curing distance on the EC of bulk-fill RBCs is material dependent. Notwithstanding the light-curing distance, the EC of the FK and TN is below the threshold HR value of 0.8 when photopolymerized for 20 s in 4 mm increments in black opaque molds. | ||
546 | |a EN | ||
690 | |a Composite resins | ||
690 | |a Curing light | ||
690 | |a Hardness | ||
690 | |a Medicine | ||
690 | |a R | ||
690 | |a Dentistry | ||
690 | |a RK1-715 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n Saudi Dental Journal, Vol 33, Iss 8, Pp 1184-1189 (2021) | |
787 | 0 | |n http://www.sciencedirect.com/science/article/pii/S1013905221000031 | |
787 | 0 | |n https://doaj.org/toc/1013-9052 | |
856 | 4 | 1 | |u https://doaj.org/article/fa3e8e94243a4ad88a2e002da2a9a8c7 |z Connect to this object online. |