Impact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites

Objective: To investigate the effect of light-curing distance on the effectiveness of cure (EC) of bulk-fill resin-based composites (RBCs). Materials and methods: Two bulk-fill RBCs (a Tetric N-Ceram Bulk Fill (TN) and a Filtek Bulk Fill (FK)) are evaluated. Specimens (4 mm high) are cured for 20 s...

Full description

Saved in:
Bibliographic Details
Main Authors: Rana Abdelbaset Diab (Author), Adrian Ujin Yap (Author), Maria Angela Garcia Gonzalez (Author), Noor Azlin Yahya (Author)
Format: Book
Published: Elsevier, 2021-12-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_fa3e8e94243a4ad88a2e002da2a9a8c7
042 |a dc 
100 1 0 |a Rana Abdelbaset Diab  |e author 
700 1 0 |a Adrian Ujin Yap  |e author 
700 1 0 |a Maria Angela Garcia Gonzalez  |e author 
700 1 0 |a Noor Azlin Yahya  |e author 
245 0 0 |a Impact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites 
260 |b Elsevier,   |c 2021-12-01T00:00:00Z. 
500 |a 1013-9052 
500 |a 10.1016/j.sdentj.2021.01.003 
520 |a Objective: To investigate the effect of light-curing distance on the effectiveness of cure (EC) of bulk-fill resin-based composites (RBCs). Materials and methods: Two bulk-fill RBCs (a Tetric N-Ceram Bulk Fill (TN) and a Filtek Bulk Fill (FK)) are evaluated. Specimens (4 mm high) are cured for 20 s at different distances (0 mm (D0), 2 mm (D2), 4 mm (D4), 6 mm (D6) and 8 mm (D8)) and stored for 24 h in 100% relative humidity at 37 °C. The top and bottom surface hardness (SH) (n = 12) are assessed using a Knoop microhardness tester and the EC is calculated. The EC is characterized by the hardness ratio (HR) (mean bottom: top SH). An HR of 0.8 is used as the benchmark for an effective/adequate cure. Data are analyzed using one-way analysis of variance and Tukey's post hoc test (α = 0.05). Correlations between the top and bottom surfaces are examined using the Pearson correlation (α = 0.05). Results: For the TN, the HR at D8 is significantly lower than all other light-curing distances, while for the FK, it is significantly lower than D0 only. Conclusion: The effect of light-curing distance on the EC of bulk-fill RBCs is material dependent. Notwithstanding the light-curing distance, the EC of the FK and TN is below the threshold HR value of 0.8 when photopolymerized for 20 s in 4 mm increments in black opaque molds. 
546 |a EN 
690 |a Composite resins 
690 |a Curing light 
690 |a Hardness 
690 |a Medicine 
690 |a R 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Saudi Dental Journal, Vol 33, Iss 8, Pp 1184-1189 (2021) 
787 0 |n http://www.sciencedirect.com/science/article/pii/S1013905221000031 
787 0 |n https://doaj.org/toc/1013-9052 
856 4 1 |u https://doaj.org/article/fa3e8e94243a4ad88a2e002da2a9a8c7  |z Connect to this object online.