Bond strength of relined print and conventional denture base resins after aging

Objectives: To compare the bond strength of printed and conventionally produced denture base resins to reline resins after being submitted to a physical-chemical aging process. Methods: Sixty specimens (10×10×3.3 mm) of two printed (V-Print Dentbase and Denture 3D+) and one conventionally produced (...

Full description

Saved in:
Bibliographic Details
Main Authors: Sofia Brito Morais (Author), Ana Bettencourt (Author), Jaime Portugal (Author), Cristina Bettencourt Neves (Author)
Format: Book
Published: Sociedade Portuguesa de Estomatologia e Medicina Dentária, 2023-09-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_fa5f9bf8fe1f47a38f7b64bbb27daef3
042 |a dc 
100 1 0 |a Sofia Brito Morais  |e author 
700 1 0 |a Ana Bettencourt  |e author 
700 1 0 |a Jaime Portugal  |e author 
700 1 0 |a Cristina Bettencourt Neves  |e author 
245 0 0 |a Bond strength of relined print and conventional denture base resins after aging 
260 |b Sociedade Portuguesa de Estomatologia e Medicina Dentária,   |c 2023-09-01T00:00:00Z. 
500 |a 10.24873/j.rpemd.2023.08.1063 
500 |a 1646-2890 
500 |a 1647-6700 
520 |a Objectives: To compare the bond strength of printed and conventionally produced denture base resins to reline resins after being submitted to a physical-chemical aging process. Methods: Sixty specimens (10×10×3.3 mm) of two printed (V-Print Dentbase and Denture 3D+) and one conventionally produced (Probase Hot) denture base resins were relined with two acrylic resins: Ufi Gel Hard C and Probase Cold (n=10). The specimens were submitted to 1000 cycles of thermal fluctuations (5-55ºC) and 28 days of pH cycles using pH=3 (8 h/day) and pH=7 (16 h/day). Then, the shear bond strength was evaluated (1 KN; 1 mm/min), and the failure mode was classified as adhesive, cohesive, or mixed type. Data were analyzed with Kruskal-Wallis and t-tests (?=0.05). Results: Bond strength values ranged from 8.9 to 21.5 MPa. No statistically significant (p=0.07) differences were found between the bond strength of the three denture base acrylic resins. The reline resin did not significantly (p=0.07) affect the bond strength of the two printed resins. However, relining the Probase Hot with Probase Cold yielded a higher bond strength (p<0.001) than with Ufi Gel Hard C. Only the Probase Hot-Ufi Gel Hard C group revealed 100% of failures classified as adhesive type. Conclusions: The two printed denture base resins obtained similar bond strength to conventionally produced denture base resin after being submitted to thermal and chemical aging. 
546 |a EN 
546 |a PT 
690 |a adhesion 
690 |a cad-cam polymers 
690 |a chemical aging 
690 |a thermal aging 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Revista Portuguesa de Estomatologia, Medicina Dentária e Cirurgia Maxilofacial, Vol 64, Iss 3, Pp 105-111 (2023) 
787 0 |n https://administracao.spemd.pt/app/assets/imagens/files_img/1_19_651be0b042788.pdf 
787 0 |n https://doaj.org/toc/1646-2890 
787 0 |n https://doaj.org/toc/1647-6700 
856 4 1 |u https://doaj.org/article/fa5f9bf8fe1f47a38f7b64bbb27daef3  |z Connect to this object online.