Comparative evaluation of three different glass ionomer cements

Context: Newer glass ionomer cements with improved properties are constantly being developed. One such material is the novel Hybrid Glass-Ionomer cement (HGIC) with properties yet to be studied. Aims: The aim of this study was to compare the flexural strength, shear bond strength, wear resistance an...

Full description

Saved in:
Bibliographic Details
Main Authors: T Hari Sainath Reddy (Author), K Vijay Venkatesh (Author), Rekha Mani (Author)
Format: Book
Published: Wolters Kluwer Medknow Publications, 2021-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_fd4bb80d2b5943ffba7e856fc7a516d0
042 |a dc 
100 1 0 |a T Hari Sainath Reddy  |e author 
700 1 0 |a K Vijay Venkatesh  |e author 
700 1 0 |a Rekha Mani  |e author 
245 0 0 |a Comparative evaluation of three different glass ionomer cements 
260 |b Wolters Kluwer Medknow Publications,   |c 2021-01-01T00:00:00Z. 
500 |a 0970-9290 
500 |a 1998-3603 
500 |a 10.4103/ijdr.ijdr_603_21 
520 |a Context: Newer glass ionomer cements with improved properties are constantly being developed. One such material is the novel Hybrid Glass-Ionomer cement (HGIC) with properties yet to be studied. Aims: The aim of this study was to compare the flexural strength, shear bond strength, wear resistance and fluoride release of Hybrid Glass Ionomer restorative with Conventional Glass Ionomer Cement (CGIC) and Resin modified Glass Ionomer Cement (RMGIC). Settings and Design: This was an in vitro study. Methods and Material: A total of 300 samples were tested in this study, with 100 samples per group and each group was further subdivided into 5 sub-groups with 20 samples each. Flexural and Shear bond strength values were determined by subjecting the specimens to a universal testing machine. For wear resistance, the specimens were assessed using a pin on the disc tribometer. For fluoride release, the test specimen suspended in 10 mL deionised water was tested at 24 h and 1 week. Statistical Analysis Used: One-way ANOVA. Results: RMGIC had the highest flexural and shear bond strength values followed by HGIC and CGIC. HGIC had the least wear rate followed by RMGIC and CGIC. At 24 h and 1 week, HGIC had the highest fluoride release among the study groups. Conclusions: HGIC exhibited the highest wear resistance and fluoride release among the cements studied. However, flexural and Shear bond strength values, of RMGIC, was comparatively higher. 
546 |a EN 
690 |a flexural strength 
690 |a fluoride release 
690 |a glass ionomer 
690 |a shear bond strength 
690 |a wear resistance 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Indian Journal of Dental Research, Vol 32, Iss 4, Pp 485-488 (2021) 
787 0 |n http://www.ijdr.in/article.asp?issn=0970-9290;year=2021;volume=32;issue=4;spage=485;epage=488;aulast=Sainath 
787 0 |n https://doaj.org/toc/0970-9290 
787 0 |n https://doaj.org/toc/1998-3603 
856 4 1 |u https://doaj.org/article/fd4bb80d2b5943ffba7e856fc7a516d0  |z Connect to this object online.