Validation of two methods of skin fold and bioelectrical impedance with hydrostatic method for determining the body fat percent in active men

Validation of two methods of skin fold and bioelectrical impedance withhydrostatic method for determining the body fat percent in active menAbstractPurpose: This study was conducted to determine the validity and reliability of skin fold andbioelectrical impedance methods in detecting body fat percen...

Full description

Saved in:
Bibliographic Details
Main Authors: علی برزگری (Author), سعید شاکریان (Author), ایوب مهدی وند (Author), لیلا ضامنی (Author)
Format: Book
Published: Shahid Beheshti University, 2009-11-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_fd54791e4cd54a82b596ce449d2e0d0c
042 |a dc 
100 1 0 |a علی برزگری  |e author 
700 1 0 |a سعید شاکریان  |e author 
700 1 0 |a ایوب مهدی وند  |e author 
700 1 0 |a لیلا ضامنی  |e author 
245 0 0 |a Validation of two methods of skin fold and bioelectrical impedance with hydrostatic method for determining the body fat percent in active men 
260 |b Shahid Beheshti University,   |c 2009-11-01T00:00:00Z. 
500 |a 2676-3710 
500 |a 2645-4041 
500 |a 10.48308/joeppa.2009.98554 
520 |a Validation of two methods of skin fold and bioelectrical impedance withhydrostatic method for determining the body fat percent in active menAbstractPurpose: This study was conducted to determine the validity and reliability of skin fold andbioelectrical impedance methods in detecting body fat percent in comparison to the hydrostaticmethod. Methods: For this reason, 40 students of Shahid Chamran University of Ahvaz (age,22.2±2.73 years; height, 176.27±6.08 cm; and weight, 69.92±7.41 kg) were randomly chosen.Body density (BD) was determined by using hydrostatic, skin fold (seven site equation of Jackson& Pollock) and bioelectrical impedance (BIA) methods. Thereafter, body fat percent (BF%) wascalculated for all methods using the Siri's equation. Statistical analyses were performed usingPearson's correlation coefficient and paired t-test at P<0.05. Results: Data analysis showed asignificant difference between skin fold method and hydrostatic method (R=0.959, P<0.001). Thevalidity of BIA machine in comparison with criterion method was confirmed (R=0.946, P<0.05).Conclusions: Based on the findings of this investigation, it could be concluded that the BIAmethod is suitable method for determining body fat percent in active men and it could be a goodreplacement for the expensive hydrostatic method. 
546 |a FA 
690 |a validity 
690 |a body fat percent 
690 |a bioelectrical impedance 
690 |a skin fold 
690 |a Sports medicine 
690 |a RC1200-1245 
655 7 |a article  |2 local 
786 0 |n فیزیولوژی ورزش و فعالیت بدنی, Vol 2, Iss 2 (2009) 
787 0 |n https://joeppa.sbu.ac.ir/article_98554_2106e9906116c4bc645e2bf7377e7d09.pdf 
787 0 |n https://doaj.org/toc/2676-3710 
787 0 |n https://doaj.org/toc/2645-4041 
856 4 1 |u https://doaj.org/article/fd54791e4cd54a82b596ce449d2e0d0c  |z Connect to this object online.