A comparative evaluation of the variations on the shades of pressable ceramic system with the layering technique after different number of firing cycles: An in vitro study

Aim: The main aim of the present study was to compare and evaluate the effect of repetitive firings on different shades of a pressable all ceramic system layered with veneering porcelain. Setting and Design: In-vitro comparative study Materials And Methods: An in vitro comparative study was conducte...

Deskribapen osoa

Gorde:
Xehetasun bibliografikoak
Egile Nagusiak: Manupreet Kaur (Egilea), Shailendra Kumar Sahu (Egilea)
Formatua: Liburua
Argitaratua: Wolters Kluwer Medknow Publications, 2024-04-01T00:00:00Z.
Gaiak:
Sarrera elektronikoa:Connect to this object online.
Etiketak: Etiketa erantsi
Etiketarik gabe, Izan zaitez lehena erregistro honi etiketa jartzen!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_fd8ab9f4c24d40fd8482aad2277e7dfb
042 |a dc 
100 1 0 |a Manupreet Kaur  |e author 
700 1 0 |a Shailendra Kumar Sahu  |e author 
245 0 0 |a A comparative evaluation of the variations on the shades of pressable ceramic system with the layering technique after different number of firing cycles: An in vitro study 
260 |b Wolters Kluwer Medknow Publications,   |c 2024-04-01T00:00:00Z. 
500 |a 0972-4052 
500 |a 1998-4057 
500 |a 10.4103/jips.jips_421_23 
520 |a Aim: The main aim of the present study was to compare and evaluate the effect of repetitive firings on different shades of a pressable all ceramic system layered with veneering porcelain. Setting and Design: In-vitro comparative study Materials And Methods: An in vitro comparative study was conducted, and a total of 60 disc shaped specimens (15 mm in diameter and 0.8 mm in thickness) were made of heat pressed ceramic of shades A2, A3, and B2 (20 discs of each shade) grouped as Group I, II, and III, respectively, using the lost wax technique. The discs were subsequently layered with veneering porcelain followed by glazing and overglazing and underwent a firing cycle at each step until six times combined. CIE L*a*b* measurements were noted on each sample after the third, fourth, fifth, and sixth firing using VITA Easyshade Advance 4.0 spectrophotometer. Statistical Analysis Used: Statistical Analysis was done by SPSS 17.0 software. One way analysis of variance, multiple comparisons using the Tukey test, and descriptive statistical analysis were done for all the groups in the study. P <0.05 was statistically significant. Results: The mean color differences for the repeated firings were imperceptible (ΔE <1.67) to the human eye for all ceramic samples tested except between the fourth and fifth firing of Group II (shade A3). Conclusion: The analysis revealed that although repeated firings lead to changes in L*, a*, and b* values, the mean color difference was below the clinically acceptable color change (ΔE <3.7). 
546 |a EN 
690 |a firing cycle 
690 |a porcelain 
690 |a spectrophotometer 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n The Journal of Indian Prosthodontic Society, Vol 24, Iss 2, Pp 144-151 (2024) 