Chapter 11 Prinsipper ved test-retest-reliabilitet

"The study aim was twofold: 1) Review basic principles of test-retest reliability, and 2) investigate the reliability of a test procedure of a one-minute time trial on an ergometer bicycle in relatively well-trained young adults. The subjects (N = 12) completed three "all-out" interva...

Ful tanımlama

Kaydedildi:
Detaylı Bibliyografya
Yazar: Haugen, Tommy (auth)
Diğer Yazarlar: Ulland Salvesen, Kjetil Marius (auth), Høigaard, Rune (auth), Salvesen, Kjetil Marius Ulland (auth)
Materyal Türü: Elektronik Kitap Bölümü
Dil:Norveççe
Baskı/Yayın Bilgisi: Oslo Cappelen Damm Akademisk/NOASP (Nordic Open Access Scholarly Publishing) 2018
Konular:
Online Erişim:OAPEN Library: download the publication
OAPEN Library: description of the publication
Etiketler: Etiketle
Etiket eklenmemiş, İlk siz ekleyin!

MARC

LEADER 00000naaaa2200000uu 4500
001 oapen_2024_20_500_12657_29592
005 20180727
003 oapen
006 m o d
007 cr|mn|---annan
008 20180727s2018 xx |||||o ||| 0|nor d
020 |a noasp.39.ch11 
020 |a 9788202596903 
040 |a oapen  |c oapen 
024 7 |a 10.23865/noasp.39.ch11  |c doi 
041 0 |a nor 
042 |a dc 
072 7 |a JM  |2 bicssc 
100 1 |a Haugen, Tommy  |4 auth 
700 1 |a Ulland Salvesen, Kjetil Marius  |4 auth 
700 1 |a Høigaard, Rune  |4 auth 
700 1 |a Haugen, Tommy  |4 auth 
700 1 |a Salvesen, Kjetil Marius Ulland  |4 auth 
700 1 |a Høigaard, Rune  |4 auth 
245 1 0 |a Chapter 11 Prinsipper ved test-retest-reliabilitet 
260 |a Oslo  |b Cappelen Damm Akademisk/NOASP (Nordic Open Access Scholarly Publishing)  |c 2018 
300 |a 1 electronic resource (14 p.) 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
506 0 |a Open Access  |2 star  |f Unrestricted online access 
520 |a "The study aim was twofold: 1) Review basic principles of test-retest reliability, and 2) investigate the reliability of a test procedure of a one-minute time trial on an ergometer bicycle in relatively well-trained young adults. The subjects (N = 12) completed three "all-out" intervals on the bicycle ergometers where average watt produced was recorded. The results of the experiments showed no significant mean differences across tests, high ICC (.996), low CV, TE, and SEM. The findings suggested that the ergometer test had the ability to produce accurate and stable measurements. It also indicated that measurement biases that affected the results did not seem to occur." 
520 |a "Formålet med studien var todelt: 1) Gjennomgå sentrale prinsipper for test- retest-reliabilitet, og 2) reliabilitetsteste en protokoll for maksimal innsats på sykkelrulle med ett minutts varighet hos relativt godt trente unge voksne. Forsøkspersonene (N = 12) gjennomførte tre forsøk på sykkelrulle hvor gjennomsnittwatt ble registrert. Resultatene viste ingen signifikant forskjell mellom forsøkene, høy ICC (.996), lav CV og lav TE og SEM. Resultatene indikerte at sykkeltesten har evne til å produsere nøyaktige og stabile målinger. De indikerte også at det ikke ser ut til å forkomme større systematiske feilmålinger som påvirker resultatene i betydelig grad." 
540 |a Creative Commons  |f by-4.0/  |2 cc  |4 http://creativecommons.org/licenses/by-4.0/ 
546 |a Norwegian 
650 7 |a Psychology  |2 bicssc 
653 |a reliability test 
653 |a bicycle ergometer 
653 |a effort 
653 |a performance 
653 |a reliabilitetstest 
653 |a sykkelergometer 
653 |a innsats 
653 |a prestasjon 
773 1 0 |t Trender for idrettspsykologisk forskning i Skandinavia  |7 nnaa  |o OAPEN Library UUID: 387ce5c2-7055-4af1-99b5-973279fb12bb 
856 4 0 |a www.oapen.org  |u https://library.oapen.org/bitstream/id/23d45bc9-114a-4b3a-b858-1119f09cc398/Trender_Kapittel 11.pdf  |7 0  |z OAPEN Library: download the publication 
856 4 0 |a www.oapen.org  |u http://library.oapen.org/handle/20.500.12657/29592  |7 0  |z OAPEN Library: description of the publication