Chapter Measuring Energy

Data centres are part of today's critical information and communication infrastructure, and the majority of business transactions as well as much of our digital life now depend on them. At the same time, data centres are large primary energy consumers, with energy consumed by IT and server room...

Full description

Saved in:
Bibliographic Details
Main Author: Kerrison, Steve (auth)
Other Authors: Buschhoff, Markus (auth), Nunez-Yanez, Jose (auth), Eder, Kerstin (auth)
Format: Electronic Book Chapter
Language:English
Published: InTechOpen 2017
Subjects:
Online Access:OAPEN Library: download the publication
OAPEN Library: description of the publication
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000naaaa2200000uu 4500
001 oapen_2024_20_500_12657_49191
005 20210602
003 oapen
006 m o d
007 cr|mn|---annan
008 20210602s2017 xx |||||o ||| 0|eng d
020 |a 65989 
040 |a oapen  |c oapen 
024 7 |a 10.5772/65989  |c doi 
041 0 |a eng 
042 |a dc 
072 7 |a RNU  |2 bicssc 
100 1 |a Kerrison, Steve  |4 auth 
700 1 |a Buschhoff, Markus  |4 auth 
700 1 |a Nunez-Yanez, Jose  |4 auth 
700 1 |a Eder, Kerstin  |4 auth 
245 1 0 |a Chapter Measuring Energy 
260 |b InTechOpen  |c 2017 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
506 0 |a Open Access  |2 star  |f Unrestricted online access 
520 |a Data centres are part of today's critical information and communication infrastructure, and the majority of business transactions as well as much of our digital life now depend on them. At the same time, data centres are large primary energy consumers, with energy consumed by IT and server room air conditioning equipment and also by general building facilities. In many data centres, IT equipment energy and cooling energy requirements are not always coordinated, so energy consumption is not optimised. Most data centres lack an integrated energy management system that jointly optimises and controls all its energy consuming equipments in order to reduce energy consumption and increase the usage of local renewable energy sources. In this chapter, the authors discuss the challenges of coordinated energy management in data centres and present a novel scalable, integrated energy management system architecture for data centre wide optimisation. A prototype of the system has been implemented, including joint workload and thermal management algorithms. The control algorithms are evaluated in an accurate simulation‐based model of a real data centre. Results show significant energy savings potential, in some cases up to 40%, by integrating workload and thermal management. 
540 |a Creative Commons  |f https://creativecommons.org/licenses/by/3.0/  |2 cc  |4 https://creativecommons.org/licenses/by/3.0/ 
546 |a English 
650 7 |a Sustainability  |2 bicssc 
653 |a energy efficient data centres, workload management, thermal management, integrated data centre energy management platform 
773 1 0 |7 nnaa 
856 4 0 |a www.oapen.org  |u https://library.oapen.org/bitstream/id/c56673b3-5998-4087-bb2e-0d72e24b7c6f/53179.pdf  |7 0  |z OAPEN Library: download the publication 
856 4 0 |a www.oapen.org  |u https://library.oapen.org/handle/20.500.12657/49191  |7 0  |z OAPEN Library: description of the publication