Efficacy and Safety of Different Energy Settings for Atrial Fibrillation Ablation using the Duty-cycled Radiofrequency Ablation Catheter (PVAC)
<p>In recent years, new ablation catheters have been developed to facilitate atrial fibrillation (AF) ablation procedures, including the multi-electrode pulmonary vein ablation catheter (PVAC), capable of using different proportions of unipolar and bipolar energy. The purpose of this study was...
Enregistré dans:
Auteurs principaux: | , , , |
---|---|
Format: | Livre |
Publié: |
Journal of Cardiovascular Medicine and Cardiology - Peertechz Publications,
2014-07-07.
|
Sujets: | |
Accès en ligne: | Connect to this object online. |
Tags: |
Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | peertech__10_17352_2455-2976_000002 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Stefan Lönnerholm |e author |
700 | 1 | 0 | |a Helena Malmborg |e author |
700 | 1 | 0 | |a Per Blomström |e author |
700 | 1 | 0 | |a Carina Blomström-Lundqvist |e author |
245 | 0 | 0 | |a Efficacy and Safety of Different Energy Settings for Atrial Fibrillation Ablation using the Duty-cycled Radiofrequency Ablation Catheter (PVAC) |
260 | |b Journal of Cardiovascular Medicine and Cardiology - Peertechz Publications, |c 2014-07-07. | ||
520 | |a <p>In recent years, new ablation catheters have been developed to facilitate atrial fibrillation (AF) ablation procedures, including the multi-electrode pulmonary vein ablation catheter (PVAC), capable of using different proportions of unipolar and bipolar energy. The purpose of this study was to evaluate the acute efficacy, as well as safety, when using the two different energy settings for the PVAC catheter.</p><p><strong>Methods and Results: </strong>Thirty-five patients with a mean age of 62 ± 7.7 years with paroxysmal (54%) or persistent AF were included in the study and randomized to 4:1 versus 2:1 bipolar/unipolar energy setting with the PVAC device. The mean number of applications with the PVAC catheter was 41 ± 10 and 51 ± 15 (p = 0.3) respectively with the 4:1 and the 2:1 setting. Touch-up with another RF ablation catheter was necessary in 3 and 7 patients respectively in the 4:1 and 2:1 group. The procedure time was 155 ± 35 and 174 ± 41minutes respectively and the total fluoroscopy time, including the time for touch-up with another catheter, was 42 ± 14 and 50 ± 17 minutes respectively with the 4:1 versus 2:1 setting. No complications were seen in any group. <br></p><p><strong>Conclusion: </strong>There was no significant difference between the 4:1 and 2:1 bipolar-tounipolar energy setting with the PVAC regarding the number of applications needed to create (PVI), the number of patients in which (PVI) could be achieved without touch-up applications, the procedure time or the fluoroscopy time.</p> | ||
540 | |a Copyright © Stefan Lönnerholm et al. | ||
546 | |a en | ||
655 | 7 | |a Research Article |2 local | |
856 | 4 | 1 | |u https://doi.org/10.17352/2455-2976.000002 |z Connect to this object online. |