<p><strong>Aims</strong>: Mechanical force applied during leads removal is the main cause for major complications and</p><p>cardiovascular injuries. Aim of this study was to retrospectively analyse safety and effectiveness of a</p><p>stepwise interdisciplina...

Full description

Saved in:
Bibliographic Details
Main Authors: Valentino Borghetti (Author), Giovanni Carreras (Author), Chiara Marini (Author), Stefano Donzelli (Author), Giancarlo D'Addario (Author), Enrico Boschetti (Author), Alessandro Pardini (Author)
Format: Book
Published: Journal of Cardiovascular Medicine and Cardiology - Peertechz Publications, 2018-10-30.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 peertech__10_17352_2455-2976_000073
042 |a dc 
100 1 0 |a Valentino Borghetti  |e author 
700 1 0 |a  Giovanni Carreras  |e author 
700 1 0 |a  Chiara Marini  |e author 
700 1 0 |a  Stefano Donzelli  |e author 
700 1 0 |a  Giancarlo D'Addario  |e author 
700 1 0 |a  Enrico Boschetti  |e author 
700 1 0 |a Alessandro Pardini  |e author 
245 0 0 |a Interdisciplinary stepwise approach for an effective and safe Mechanical Transvenous Lead Extraction 
260 |b Journal of Cardiovascular Medicine and Cardiology - Peertechz Publications,   |c 2018-10-30. 
520 |a <p><strong>Aims</strong>: Mechanical force applied during leads removal is the main cause for major complications and</p><p>cardiovascular injuries. Aim of this study was to retrospectively analyse safety and effectiveness of a</p><p>stepwise interdisciplinary approach for mechanical transvenous lead extraction.</p><p><strong>Methods</strong>: From February 2011 to December 2017, 71 patients (pts) underwent electronic leads</p><p>extraction for Cardiac Implantable Electronic Devices (CIED) complications. Mean age was 70±11 years</p><p>(range 34-92). A total of 160 leads were managed with a mean time from implantation to extraction of</p><p>33±39 months (range 4-300). Lead type were atrial (37%), Ventricular (49%) and Coronary sinus (14%).</p><p>Indication for lead removal were pocket/lead erosion (73%), isolated lead infection (10%), dysfunction or</p><p>upgrading (17%), respectively. Data on algorithm of treatment, procedural success, complications as well</p><p>as 30 day mortality are reported.</p> 
540 |a Copyright © Valentino Borghetti et al. 
546 |a en 
655 7 |a Research Article  |2 local 
856 4 1 |u https://doi.org/10.17352/2455-2976.000073  |z Connect to this object online.