The Buddy Ballooning Technique- A simple debulking technique

<p>The author describes a simple and inexpensive way to deliver high pressures within an atherosclerotic coronary artery and reports two cases. The technique used two non-compliant (NC) balloons placed in parallel and inflated together within the same coronary segment. The cases illustrate two...

Full description

Saved in:
Bibliographic Details
Main Author: Vincent Dangoisse (Author)
Format: Book
Published: Journal of Cardiovascular Medicine and Cardiology - Peertechz Publications, 2018-12-08.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 peertech__10_17352_2455-2976_000078
042 |a dc 
100 1 0 |a Vincent Dangoisse  |e author 
245 0 0 |a The Buddy Ballooning Technique- A simple debulking technique 
260 |b Journal of Cardiovascular Medicine and Cardiology - Peertechz Publications,   |c 2018-12-08. 
520 |a <p>The author describes a simple and inexpensive way to deliver high pressures within an atherosclerotic coronary artery and reports two cases. The technique used two non-compliant (NC) balloons placed in parallel and inflated together within the same coronary segment. The cases illustrate two possible indications for the technique: lesion resistant to one adequately sized NC balloon or not fully expanded coronary stents after high-pressure non-compliant ballooning.</p> 