Investigation of the effectiveness of ECOLAB 'Drape ArmourTM' Radiation Protection in limiting eye-lens doses of healthcare personnel exposed to ionizing radiation during gastroenterology - interventional radiology procedures
<p>Objectives: To investigate the efficiency of the ECOLAB "Drape ArmourTM" device in limiting the eye-lens doses absorbed by healthcare personnel exposed to ionizing radiation, in a four-month trial during gastroenterology interventional radiology procedures. </p><p>Meth...
Saved in:
Main Authors: | , , , , , , , , |
---|---|
Format: | Book |
Published: |
Global Journal of Cancer Therapy - Peertechz Publications,
2022-10-20.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | peertech__10_17352_2581-5407_000048 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Fulvio IM Fucilli |e author |
700 | 1 | 0 | |a Giuseppe Di Giovanni |e author |
700 | 1 | 0 | |a Alessandro Mastrorocco |e author |
700 | 1 | 0 | |a Matteo Ninni |e author |
700 | 1 | 0 | |a Piero Loprete |e author |
700 | 1 | 0 | |a Isa De Crudis |e author |
700 | 1 | 0 | |a Massimiliano Marano |e author |
700 | 1 | 0 | |a Antonio Santomauro |e author |
700 | 1 | 0 | |a Fabio Fucilli |e author |
245 | 0 | 0 | |a Investigation of the effectiveness of ECOLAB 'Drape ArmourTM' Radiation Protection in limiting eye-lens doses of healthcare personnel exposed to ionizing radiation during gastroenterology - interventional radiology procedures |
260 | |b Global Journal of Cancer Therapy - Peertechz Publications, |c 2022-10-20. | ||
520 | |a <p>Objectives: To investigate the efficiency of the ECOLAB "Drape ArmourTM" device in limiting the eye-lens doses absorbed by healthcare personnel exposed to ionizing radiation, in a four-month trial during gastroenterology interventional radiology procedures. </p><p>Methods: Eyelens doses measured with eye-lens dosimeters calibrated in terms of equivalent dose at 3 mm depth ( Hp(3) ) were collected and analyzed since 2016 along with the irradiation parameters (Dose Area Product - DAP). </p><p>The eye-lens doses received during the four-month trial, have been compared with doses normally received, in the same conditions of irradiation, in the absence of the protection drape.</p><p>Results: During the period of use of Drape ArmourTM, the average dose to the eye lens was estimated to be 0.73 mSv (St.dev = 0.40 mSv). The average dose to the eye lens, measured in the same four-month period, across different years from 2017 to 2021, was equal to 1.30 mSv (st. dev = 0.35 mSv).</p><p>Conclusions: Results suggest the effectiveness of Drape ArmourTM in containing the doses to the eye lens.</p><p>Keypoint: Limiting eye-lens doses to a maximum value of 20 mSv/year is a real challenge, especially in interventional radiologic facilities. The use of suitable radio-opaque drapes may help healthcare workers involved in such facilities. The aim of the work is to evaluate the efficiency of the ECOLAB "Drape ArmourTM" sterile mono-use drape.</p> | ||
540 | |a Copyright © Fulvio IM Fucilli et al. | ||
546 | |a en | ||
655 | 7 | |a Clinical Techniques |2 local | |
856 | 4 | 1 | |u https://doi.org/10.17352/2581-5407.000048 |z Connect to this object online. |