Developing analytical parameters and evaluation of thermo fisher urinary creatinine enzymatic method to implement in open system chemistry analyzers

<p>Creatinine assay is used mainly to monitor kidney function and for sample validity when testing for drugs of abuse. Creatinine alkaline picrate method based on Jaffe's reaction calls for extra cleaning procedures to minimize interference from picric acid and sodium hydroxide. Thermo Fi...

Full description

Saved in:
Bibliographic Details
Main Authors: Ashraf Mina (Author), Leah McNeice (Author), Shanmugam Banukumar (Author), Santiago Vazquez (Author)
Format: Book
Published: International Journal of Pharmaceutical Sciences and Developmental Research - Peertechz Publications, 2020-09-16.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 peertech__10_17352_ijpsdr_000031
042 |a dc 
100 1 0 |a Ashraf Mina  |e author 
700 1 0 |a  Leah McNeice  |e author 
700 1 0 |a  Shanmugam Banukumar  |e author 
700 1 0 |a Santiago Vazquez  |e author 
245 0 0 |a Developing analytical parameters and evaluation of thermo fisher urinary creatinine enzymatic method to implement in open system chemistry analyzers 
260 |b International Journal of Pharmaceutical Sciences and Developmental Research - Peertechz Publications,   |c 2020-09-16. 
520 |a <p>Creatinine assay is used mainly to monitor kidney function and for sample validity when testing for drugs of abuse. Creatinine alkaline picrate method based on Jaffe's reaction calls for extra cleaning procedures to minimize interference from picric acid and sodium hydroxide. Thermo Fisher enzymatic method is more sensitive and specific when compared to alkaline picrate method, but there were no available analytical parameters to setup this enzymatic method on open chemistry analyses platform such as Beckman-Coulter AU5800 analyser. Specific analytical parameters were developed and the assay performance is evaluated against the alkaline picrate method.  We successfully set up analytical parameters on Beckman-Coulter AU5800, as an example of open system analyser, and evaluated its performance against Thermo Fisher Jaffe's reaction method. The weighted Deming regression analysis for 408 samples showed a good correlation at a 95% confidence interval. Slope is 1.065 to 1.091, Y-intercept when X=0.0 is -0.9377 to -0.5443 and correlation coefficient (r) is 0.993. The alkaline picrate method Mean and SD for tested samples are 13.2877 and 7.414 respectively and for the enzymatic method are 13.5823 and 7.987 respectively. Many interferences from drugs and other substances are eliminated when using the enzymatic method and the stability of other reagents on-board improved because the reagents used in the enzymatic method are less invasive.</p> 
540 |a Copyright © Ashraf Mina et al. 
546 |a en 
655 7 |a Research Article  |2 local 
856 4 1 |u https://doi.org/10.17352/ijpsdr.000031  |z Connect to this object online.