Magnetic Resonance Imaging versus Proton Magnetic Resonance Spectroscopy in Neonatal Hypoxic Ischemic Encephalopathy in Egyptian Population: Pilot study

<p><strong>Background</strong>: Hypoxic-ischemic encephalopathy (HIE) is a serious condition that results of critical failure of the intrapartum gas exchange and may lead to a signifi cant damage in the central nervous system.</p><p><strong>Objective</strong>...

Полное описание

Сохранить в:
Библиографические подробности
Главные авторы: Ossama Y Mansour (Автор), Doaa Hanfy (Автор), Sameh Fathy (Автор), Rania E Mohammed (Автор)
Формат:
Опубликовано: Journal of Neurology, Neurological Science and Disorders - Peertechz Publications, 2017-08-30.
Предметы:
Online-ссылка:Connect to this object online.
Метки: Добавить метку
Нет меток, Требуется 1-ая метка записи!
Описание
Итог:<p><strong>Background</strong>: Hypoxic-ischemic encephalopathy (HIE) is a serious condition that results of critical failure of the intrapartum gas exchange and may lead to a signifi cant damage in the central nervous system.</p><p><strong>Objective</strong>: to elucidate the role of brain magnetic resonance imaging (MRI) versus Proton magnetic resonance spectroscopy (1H-MRS) in the diagnosis and evaluating the severity of HIE in full-term Egyptian neonates</p><p><strong>Design</strong>: 49-months observational controlled study.</p><p><strong>Setting</strong>: Pediatric neurology and Radiology Departments, Alexandria University Hospital        <br></p><p> <strong>Patients and Methods</strong>: Thirty full-term neonates in the fi rst two weeks with HIE (Sarnat staging) were included (18 males and 12 females), with exclusion of those with congenital brain malformation and/ or<br>perinatal infection in addition to 15 age- and sex- matched healthy controls. All patients and controls were<br>examined with brain MRI and 1H-MRS. <br></p><p><strong>Results</strong>: In neonates with HIE, the percent of agreement between clinical staging, and MRI grading<br>was 66.67 while it was 76.67 regarding 1H-MRS grading. The sensitivity for MRI was 66.67%, specifi city<br>was 75%, accuracy was 77.78%, PPV was 80% and NPV was 75%. Meanwhile, the sensitivity for 1H-MRS<br>was 92%, specifi city was 75%, accuracy was 84.44%, PPV was 82.14% and NPV was 88.24%.</p><p><strong>Conclusion</strong>: 1H-MRS detected more percent of agreement, true positive and less false negative cases<br>than MRI. Despite the equal specifi city between them, still 1H-MRS got more sensitivity, accuracy, PPV<br>and NPV than MRI i.e. when we have to choose early and single investigation it is recommended to choose<br>1H-MRS.<strong></strong></p>
DOI:10.17352/jnnsd.000020