Effect of varied probe length on the resonant frequency of a circular cross-sectional cavity / Mohd Khairul Mohd Salleh ... [et al.]
A simple design of a metallic circular cross-sectional air-filled cavity is presented. Two probes of varied lengths are used to excite TE112-mode wave into the cavity to give a resonant frequency of 5.86 GHz. The experiments show that the resonant frequency of the cavity resonator decreases as the l...
Salvato in:
Autori principali: | , , , |
---|---|
Natura: | Libro |
Pubblicazione: |
Institute of Research, Development and Commercialisation (IRDC),
2005.
|
Soggetti: | |
Accesso online: | Link Metadata |
Tags: |
Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
|
Riassunto: | A simple design of a metallic circular cross-sectional air-filled cavity is presented. Two probes of varied lengths are used to excite TE112-mode wave into the cavity to give a resonant frequency of 5.86 GHz. The experiments show that the resonant frequency of the cavity resonator decreases as the lengths of the probes are increased. The shortest probe in the range of study gives the closest resonant frequency to the one desired. |
---|---|
Descrizione del documento: | https://ir.uitm.edu.my/id/eprint/12801/1/AJ_MOHD%20KHAIRUL%20MOHD%20SALLEH%20SRJ%2005%201.pdf |