A study on compressive strength of concrete cointaining MK7003 with various water binder ratio / Clotilda Petrus ... [et al.]

The study was conducted to determine the effects of using MK7003 as a partial replacement material for OPC on the compressive strength of concrete. The study was further enhanced by studying the effects of varying the water binder ratio. Replacement level of 5%, 10% and 15% by weight of OPC in the c...

Full description

Saved in:
Bibliographic Details
Main Authors: Clotilda, Petrus (Author), Yusuff, Amer (Author), Othman, Ahmad Fairuz (Author), Mohd Zin, Ahmad Ikhwan Naim (Author)
Format: Book
Published: Universiti Teknologi MARA, Pulau Pinang & and Pusat Penerbitan Universiti (UPENA), 2005.
Subjects:
Online Access:Link Metadata
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 repouitm_14787
042 |a dc 
100 1 0 |a Clotilda, Petrus  |e author 
700 1 0 |a Yusuff, Amer  |e author 
700 1 0 |a Othman, Ahmad Fairuz  |e author 
700 1 0 |a Mohd Zin, Ahmad Ikhwan Naim  |e author 
245 0 0 |a A study on compressive strength of concrete cointaining MK7003 with various water binder ratio / Clotilda Petrus ... [et al.] 
260 |b Universiti Teknologi MARA, Pulau Pinang & and Pusat Penerbitan Universiti (UPENA),   |c 2005. 
500 |a https://ir.uitm.edu.my/id/eprint/14787/1/AJ_CLOTILDA%20PETRUS%20ESTEEM%2005.pdf 
520 |a The study was conducted to determine the effects of using MK7003 as a partial replacement material for OPC on the compressive strength of concrete. The study was further enhanced by studying the effects of varying the water binder ratio. Replacement level of 5%, 10% and 15% by weight of OPC in the control concrete were considered while maintaining water binder ratio at 0.47. Another study was conducted by varying the water binder ratios of 0.35, 0.45 and 0.55 while maintaining MK7003 content at 10% by weight. From the study it was found that increasing the level of MK7003 has a significant increase in the compressive strength of concrete but as the water binder ratio is increased the compressive strength of concrete will decrease. 
546 |a en 
690 |a Structural engineering 
690 |a Malaysia 
655 7 |a Article  |2 local 
655 7 |a PeerReviewed  |2 local 
787 0 |n https://ir.uitm.edu.my/id/eprint/14787/ 
787 0 |n https://uppp.uitm.edu.my 
856 4 1 |u https://ir.uitm.edu.my/id/eprint/14787/  |z Link Metadata