Evaluation of energy consumption in small scale distillation pot based on integral control signal for real time implementation / Nurul Nadia Mohammad ... [et al.]

This paper presents the comparative performances of PID controller with several tuning rules that includes Ziegler-Nichols, Cohen-Coon and Integral Square Error (ISE)-Load that was based on real time implementation. The characteristic of water temperature of hydro distillation process have been mode...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohammad, Nurul Nadia (Author), Marzaki, Hezri (Author), Azman, Ahmad Aftas (Author), Adnan, Ramli (Author), Tajuddin, Saiful Nizam (Author), Rahiman, Mohd Hezri Fazalul (Author)
Format: Book
Published: Faculty of Electrical Engineering, Universiti Teknologi MARA, Shah Alam, 2017-06.
Subjects:
Online Access:Link Metadata
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 repouitm_29588
042 |a dc 
100 1 0 |a Mohammad, Nurul Nadia  |e author 
700 1 0 |a Marzaki, Hezri  |e author 
700 1 0 |a Azman, Ahmad Aftas  |e author 
700 1 0 |a Adnan, Ramli  |e author 
700 1 0 |a Tajuddin, Saiful Nizam  |e author 
700 1 0 |a Rahiman, Mohd Hezri Fazalul  |e author 
245 0 0 |a Evaluation of energy consumption in small scale distillation pot based on integral control signal for real time implementation / Nurul Nadia Mohammad ... [et al.] 
260 |b Faculty of Electrical Engineering, Universiti Teknologi MARA, Shah Alam,   |c 2017-06. 
500 |a https://ir.uitm.edu.my/id/eprint/29588/1/29588.pdf 
520 |a This paper presents the comparative performances of PID controller with several tuning rules that includes Ziegler-Nichols, Cohen-Coon and Integral Square Error (ISE)-Load that was based on real time implementation. The characteristic of water temperature of hydro distillation process have been modelled by obtaining First Order Plus Dead Time (FOPDT). In this study, a setpoint was set up to 80°C to evaluate those tuning rules in term of transient responses such as settling time, rise time and percentage of overshoot. Moreover, another performance criteria in term of energy consumption have been evaluated by using integral control signal. The result shows that PID controller with Cohen Coon tuning gives the best performances for transient analyses and also gives lower energy consumption compared to other tuning rules 
546 |a en 
690 |a Devices for production of electricity by direct energy conversion 
655 7 |a Article  |2 local 
655 7 |a PeerReviewed  |2 local 
787 0 |n https://ir.uitm.edu.my/id/eprint/29588/ 
787 0 |n https://jeesr.uitm.edu.my/ 
856 4 1 |u https://ir.uitm.edu.my/id/eprint/29588/  |z Link Metadata