Electrodeposition and characterization of copper coating on stainless steel substrate from alkaline copper solution containing Ethylenediaminetetraacetate (EDTA) / Nik Norziehana Che Isa...[et al.]

Copper coating was successfully deposited onto 304 stainless steel substrate from pH 8 EDTA solution containing 0.01 M Cu2+ ions, added as CuSO4. The nature of 304 stainless steel electrode reactions in solutions was determined by cyclic voltammetry. Based on cyclic voltammetric analysis, -1.1 V is...

Full description

Saved in:
Bibliographic Details
Main Authors: Che Isa, Nik Norziehana (Author), Mohd, Yusairie (Author), Mohd Zaki, Mohammad Hafizudden (Author), Syed Mohamad, Sharifah Aminah (Author)
Format: Book
Published: Faculty of Mechanical Engineering Universiti Teknologi MARA (UiTM), 2017.
Subjects:
Online Access:Link Metadata
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 repouitm_37557
042 |a dc 
100 1 0 |a Che Isa, Nik Norziehana  |e author 
700 1 0 |a Mohd, Yusairie  |e author 
700 1 0 |a Mohd Zaki, Mohammad Hafizudden  |e author 
700 1 0 |a Syed Mohamad, Sharifah Aminah  |e author 
245 0 0 |a Electrodeposition and characterization of copper coating on stainless steel substrate from alkaline copper solution containing Ethylenediaminetetraacetate (EDTA) / Nik Norziehana Che Isa...[et al.] 
260 |b Faculty of Mechanical Engineering Universiti Teknologi MARA (UiTM),   |c 2017. 
500 |a https://ir.uitm.edu.my/id/eprint/37557/1/37557.pdf 
520 |a Copper coating was successfully deposited onto 304 stainless steel substrate from pH 8 EDTA solution containing 0.01 M Cu2+ ions, added as CuSO4. The nature of 304 stainless steel electrode reactions in solutions was determined by cyclic voltammetry. Based on cyclic voltammetric analysis, -1.1 V is related to the Cu2+ ions reduction and the suitable applied potential for further electrodeposition process. Chronoamperometric study was done by applying a constant potential at -1.1 V at different deposition times. Morphological observation revealed that deposition time has strongly affected the surface coverage of the copper coating on the 304 stainless steel surface. Crystalline pure copper phase was determined by XRD. The coating has excellent adhesion which passed the tape test. This study showed that the copper coatings with good surface coverage and adhesion can be prepared on the 304 stainless steel substrate. 
546 |a en 
690 |a TJ Mechanical engineering and machinery 
655 7 |a Article  |2 local 
655 7 |a PeerReviewed  |2 local 
787 0 |n https://ir.uitm.edu.my/id/eprint/37557/ 
787 0 |n https://jmeche.uitm.edu.my/ 
856 4 1 |u https://ir.uitm.edu.my/id/eprint/37557/  |z Link Metadata