Kinetic Study for Ultrasonic assisted Membrane Anaerobic System (UMAS) Treating Decanter Palm Oil Mill Effluent (POME) / Mansor U.Q.A....[et al.]

The discharge of Palm Oil Mill Effluent (POME) to river or sewage causes serious environmental problem and the use of Ultrasonic-assisted Membrane Anaerobic System (UMAS) is recommended as a solution. However, further use of UMAS in treating POME tends to give blockage on the membrane surface. Monod...

Full description

Saved in:
Bibliographic Details
Main Authors: U.Q.A., Mansor (Author), A., Ismail (Author), A., Yahya (Author), N.F.A., Shafie (Author), A. M., Som (Author), A.H., Nour (Author), R., Yunus (Author)
Format: Book
Published: Faculty of Mechanical Engineering Universiti Teknologi MARA (UiTM), 2017.
Subjects:
Online Access:Link Metadata
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 repouitm_38273
042 |a dc 
100 1 0 |a U.Q.A., Mansor  |e author 
700 1 0 |a A., Ismail  |e author 
700 1 0 |a A., Yahya  |e author 
700 1 0 |a N.F.A., Shafie  |e author 
700 1 0 |a A. M., Som  |e author 
700 1 0 |a A.H., Nour  |e author 
700 1 0 |a R., Yunus  |e author 
245 0 0 |a Kinetic Study for Ultrasonic assisted Membrane Anaerobic System (UMAS) Treating Decanter Palm Oil Mill Effluent (POME) / Mansor U.Q.A....[et al.] 
260 |b Faculty of Mechanical Engineering Universiti Teknologi MARA (UiTM),   |c 2017. 
500 |a https://ir.uitm.edu.my/id/eprint/38273/1/38273.pdf 
520 |a The discharge of Palm Oil Mill Effluent (POME) to river or sewage causes serious environmental problem and the use of Ultrasonic-assisted Membrane Anaerobic System (UMAS) is recommended as a solution. However, further use of UMAS in treating POME tends to give blockage on the membrane surface. Monod Model kinetic parameters of control, reacted and permeate samples of POME which contribute to membrane fouling were investigated. In this study, the treatment was operated in 5 hours at which three hours treatment was with ultrasonic application. The results show that the permeate sample has the lowest maximum specific growth rate, μmax which indicates the higher amount of biomass in UMAS reactor. The amount of biomass in UMAS was increased by using ultrasonic application which prevents the membrane from fouling problem. Therefore, it is recommended to employ UMAS in POME treatments. 
546 |a en 
690 |a TJ Mechanical engineering and machinery 
655 7 |a Article  |2 local 
655 7 |a PeerReviewed  |2 local 
787 0 |n https://ir.uitm.edu.my/id/eprint/38273/ 
856 4 1 |u https://ir.uitm.edu.my/id/eprint/38273/  |z Link Metadata