Partial discharge detection using rogowski coil sensor on medium voltage aerial bundle cable / Norhidayu Rameli ... [et al.]

It is well known that the internal partial discharge (PD) are small electric sparks that occurred due to defect in power cable insulation. This will be lead to premature failure of cable which consequently interrupt the supply on the distribution lines. In this paper, the results of internal partial...

Полное описание

Сохранить в:
Библиографические подробности
Главные авторы: Rameli, Norhidayu (Автор), Abd. Halim, Huzainie Shafi (Автор), Nor Azli, Muhd. Irfan (Автор), Anthony, Tashia Marie (Автор), Pangah @ Pa'at, Mohd Azraei (Автор), Ibrahim, Muhammad Faiz (Автор), Nor Arifin, Nur Amira (Автор)
Формат:
Опубликовано: Universiti Teknologi MARA Press (Penerbit UiTM), 2020.
Предметы:
Online-ссылка:Link Metadata
Метки: Добавить метку
Нет меток, Требуется 1-ая метка записи!
Описание
Итог:It is well known that the internal partial discharge (PD) are small electric sparks that occurred due to defect in power cable insulation. This will be lead to premature failure of cable which consequently interrupt the supply on the distribution lines. In this paper, the results of internal partial discharge detected by rogowski coil (RC) sensor were presented. The RC sensors were designed, fabricated and tested in the laboratory with varying high frequency sinusoidal and impulse signals. An artificial PD defect was also created inside a straight through joint (STJ), medium voltage aerial bundle cable (MVABC) to generate PD signals. PD testing data in the laboratory were collected and analysed. Results indicates that the RC sensors able to detects injected continuos sinusoidal signal at lower frequencies ranging from 0.5 MHz to 10 MHz. The detected PD signal generated from artificial PD defect from RC sensor were found to be slightly higher amplitude as compared to commercial PD sensor, High Frequency Current Transformer (HFCT). Thus findings shows that the RC sensor able to be used as sensor to detect the internal partial discharge at MVABC specifically at STJs.
Примечание:https://ir.uitm.edu.my/id/eprint/42390/1/42390.pdf
Partial discharge detection using rogowski coil sensor on medium voltage aerial bundle cable / Norhidayu Rameli ... [et al.]. (2020) Journal of Electrical and Electronic Systems Research (JEESR) <https://ir.uitm.edu.my/view/publication/Journal_of_Electrical_and_Electronic_Systems_Research_=28JEESR=29/>, 17. pp. 95-100. ISSN 1985-5389