Metal concentration in indoor dust of university hostel / Fazrul Razman Sulaiman and Nurul Shuhadah Baharuddin

Indoor dust has received much attention and can act as a medium for contaminant deposition, including heavy metal. This study determines the concentration of selected metal in indoor dust collected from a hostel building at Universiti Teknologi MARA Cawangan Pahang, Malaysia. This study estimates th...

Full description

Saved in:
Bibliographic Details
Main Authors: Sulaiman, Fazrul Razman (Author), Baharuddin, Nurul Shuhadah (Author)
Format: Book
Published: Universiti Teknologi MARA Cawangan Pahang, 2020-09.
Subjects:
Online Access:Link Metadata
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 repouitm_46055
042 |a dc 
100 1 0 |a Sulaiman, Fazrul Razman  |e author 
700 1 0 |a Baharuddin, Nurul Shuhadah  |e author 
245 0 0 |a Metal concentration in indoor dust of university hostel / Fazrul Razman Sulaiman and Nurul Shuhadah Baharuddin 
260 |b Universiti Teknologi MARA Cawangan Pahang,   |c 2020-09. 
500 |a https://ir.uitm.edu.my/id/eprint/46055/1/46055.pdf 
520 |a Indoor dust has received much attention and can act as a medium for contaminant deposition, including heavy metal. This study determines the concentration of selected metal in indoor dust collected from a hostel building at Universiti Teknologi MARA Cawangan Pahang, Malaysia. This study estimates the potential health risk of indoor dust exposure. Iron (Fe), copper (Cu), lead (Pb) and cadmium (Cd) were analysed using Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES). Fe dominated the results with a range of 1.28-2.50 μg/g, followed by Cu (0.37-0.76 μg/g), Pb (0.02-0.09 μg/g), and Cd (0.01-0.05 μg/g). Enrichment factor (EF), with values less than 10, suggests a mix of anthropogenic and natural sources of metal origin. The total hazard quotients (HQ) were below the level of 1, indicating low non-carcinogenic risks to adults. A comprehensive indoor dust monitoring and health risk assessment could be proposed to minimise the exposure risk in the indoor environment. 
546 |a en 
690 |a Metals 
690 |a Air pollution and its control 
690 |a Indoor air pollution. Including indoor air quality 
655 7 |a Article  |2 local 
655 7 |a PeerReviewed  |2 local 
787 0 |n https://ir.uitm.edu.my/id/eprint/46055/ 
787 0 |n http://www.gadingst.learningdistance.org/index.php/gadingst/article/view/112 
856 4 1 |u https://ir.uitm.edu.my/id/eprint/46055/  |z Link Metadata