Effect of photovoltaic (PV) module degradation rate on the greenhouse gas emissions: a life-cycle assessment / Atiqah Hamizah Mohd Nordin ...[et al.]

In this paper, a life-cycle assessment (LCA) is carried out to evaluate the greenhouse gas emissions of the photovoltaic (PV) system, focusing on the effect of the PV module degradation rate throughout the system's lifetime. The LCA is done on monocrystalline silicon PV module technology using...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohd Nordin, Atiqah Hamizah (Author), Sulaiman, Shahril Irwan (Author), Shaari, Sulaiman (Author), Mustapa, Rijalul Fahmi (Author)
Format: Book
Published: Universiti Teknologi MARA, 2021-04.
Subjects:
Online Access:Link Metadata
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 repouitm_47333
042 |a dc 
100 1 0 |a Mohd Nordin, Atiqah Hamizah  |e author 
700 1 0 |a Sulaiman, Shahril Irwan  |e author 
700 1 0 |a Shaari, Sulaiman  |e author 
700 1 0 |a Mustapa, Rijalul Fahmi  |e author 
245 0 0 |a Effect of photovoltaic (PV) module degradation rate on the greenhouse gas emissions: a life-cycle assessment / Atiqah Hamizah Mohd Nordin ...[et al.] 
260 |b Universiti Teknologi MARA,   |c 2021-04. 
500 |a https://ir.uitm.edu.my/id/eprint/47333/1/47333.pdf 
520 |a In this paper, a life-cycle assessment (LCA) is carried out to evaluate the greenhouse gas emissions of the photovoltaic (PV) system, focusing on the effect of the PV module degradation rate throughout the system's lifetime. The LCA is done on monocrystalline silicon PV module technology using actual data from manufacturers' datasheets. In this study, three different manufacturers under three scenarios are done, which involves the inclusion and exclusion of the degradation factor: i) Scenario A - PV module degradation is considered with a PR of 0.75, ii) Scenario B - PV module degradation is considered and the PR is calculated based on each PV module's temperature coefficient and other de-rating factors, iii) Scenario C - PV module degradation is ignored. Using the Intergovernmental Panel of Climate Change (IPCC 2013) impact assessment method, the results show that the greenhouse gas (GHG) emissions rate ranges from 66.05 to 79.25 g CO2-eq/kWh depending on the scenarios presented. The results also suggest that a lower degradation rate reduces the environmental burden of the PV system. 
546 |a en 
690 |a Photovoltaic power systems 
655 7 |a Article  |2 local 
655 7 |a PeerReviewed  |2 local 
787 0 |n https://ir.uitm.edu.my/id/eprint/47333/ 
787 0 |n https://jeesr.uitm.edu.my 
856 4 1 |u https://ir.uitm.edu.my/id/eprint/47333/  |z Link Metadata