Thermal comfort in free running and mechanically conditioned learning facilities / Khairul Nazli Razali and Zalida Salleh

Alhough the standard for acceptable indoor conditions for comfort cooling in non-residential buildings has been established, it is still arguable whether the standard is able to satisfy every condition since thermal comfort may be influenced by various factors. Hence, this study aims to determine th...

Full description

Saved in:
Bibliographic Details
Main Authors: Razali, Khairul Nazli (Author), Salleh, Zalida (Author)
Format: Book
Published: 2018.
Subjects:
Online Access:Link Metadata
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 repouitm_47785
042 |a dc 
100 1 0 |a Razali, Khairul Nazli  |e author 
700 1 0 |a Salleh, Zalida  |e author 
245 0 0 |a Thermal comfort in free running and mechanically conditioned learning facilities / Khairul Nazli Razali and Zalida Salleh 
260 |c 2018. 
500 |a https://ir.uitm.edu.my/id/eprint/47785/1/47785.pdf 
520 |a Alhough the standard for acceptable indoor conditions for comfort cooling in non-residential buildings has been established, it is still arguable whether the standard is able to satisfy every condition since thermal comfort may be influenced by various factors. Hence, this study aims to determine the suitable temperature that will maximize the thermal comfort at a given specific location, namely the learning facilities situated at Faculty of Architecture, Planning and Surveying (FSPU), Universiti Teknologi Mara, Shah Alam. The main objective of this study is to compare the comfort temperature obtained using two different methods namely Predicted Mean Vote, which is considered as an objective measurement, and Actual Mean Vote, which is considered as a subjective measurement. Physical parameters at four different learning facilities were taken. Three of the learning facilities are categorised as mechanically conditioned building and one is categorised as a free running building. A total of 109 students were surveyed. Comfort temperature for free running building in FSPU is found to be 27°C according to PMV and 27.10°C according to AMV. Whereas, the comfort temperature for mechanically conditioned building is found to be 24.10°C in accordance to PMV and 26.90°C in accordance to AMV. 
546 |a en 
690 |a Architecture in relation to special subjects 
690 |a Malaysia 
690 |a Energy consumption 
690 |a Energy conservation 
690 |a Renewable energy sources 
655 7 |a Conference or Workshop Item  |2 local 
655 7 |a PeerReviewed  |2 local 
787 0 |n https://ir.uitm.edu.my/id/eprint/47785/ 
787 0 |n https://icrp2018.wixsite.com/icrp18 
856 4 1 |u https://ir.uitm.edu.my/id/eprint/47785/  |z Link Metadata