Shear Bond Strength of Orthodontic Brackets Bonded With Different Curing Methods/ Faisal Ismail Bahnasi, Nagham Mohammed Abdullah and Mohamed Ibrahim Abu-Hassan

Objectives: To evaluate the effect of light-cure devices and curing times on the shear bond strength (SBS) of orthodontic brackets. Material and Methods: 60-extracted human premolars were divided into 6-groups of 10-teeth each and bonded with stainless-steel brackets by using 3M Unitek Transbond XT...

Full description

Saved in:
Bibliographic Details
Main Authors: Bahnasi, Faisal Ismail (Author), Mohammed Abdullah, Nagham (Author), Abu-Hassan, Mohamed Ibrahim (Author)
Format: Book
Published: Faculty of Dentistry, 2014.
Subjects:
Online Access:Link Metadata
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 repouitm_48927
042 |a dc 
100 1 0 |a Bahnasi, Faisal Ismail  |e author 
700 1 0 |a Mohammed Abdullah, Nagham  |e author 
700 1 0 |a Abu-Hassan, Mohamed Ibrahim  |e author 
245 0 0 |a Shear Bond Strength of Orthodontic Brackets Bonded With Different Curing Methods/ Faisal Ismail Bahnasi, Nagham Mohammed Abdullah and Mohamed Ibrahim Abu-Hassan 
260 |b Faculty of Dentistry,   |c 2014. 
500 |a https://ir.uitm.edu.my/id/eprint/48927/1/48927.pdf 
520 |a Objectives: To evaluate the effect of light-cure devices and curing times on the shear bond strength (SBS) of orthodontic brackets. Material and Methods: 60-extracted human premolars were divided into 6-groups of 10-teeth each and bonded with stainless-steel brackets by using 3M Unitek Transbond XT composite. Specimens were cured with halogen, LED and plasma arc lights with two different times for each. The specimens were subjected to shear force till debond with a crosshead speed of 1mm/min and tested after 5min. The stress was calculated and data were subjected to statistical analysis. Results: one-way ANOVA and Dunnett T3 post hoc comparison test were used. There were no significant differences between the 6 groups (p < 0.05). Conclusions: all curing light methods with loading force after 5 min achieved SBS more than the normal range; therefore, arch wire can be inserted at the same visit using any of tested curing light device or curing time. 
546 |a en 
690 |a Orthodontics 
655 7 |a Article  |2 local 
655 7 |a PeerReviewed  |2 local 
787 0 |n https://ir.uitm.edu.my/id/eprint/48927/ 
787 0 |n http://myjms.mohe.gov.my/index.php/corals/index 
856 4 1 |u https://ir.uitm.edu.my/id/eprint/48927/  |z Link Metadata