Higher educational building defects in Perak / Muhammad Syafiq Muhd Rozi and Noraini Md Zain

Education buildings are prone to building defects and their care is very important to make sure the building is safe to use and maintained. Defects in educational buildings are hazardous to users especially students. For example, education building at Beaufort, Sabah which has defect in the wall str...

Full description

Saved in:
Bibliographic Details
Main Authors: Muhd Rozi, Muhammad Syafiq (Author), Md Zain, Noraini (Author)
Format: Book
Published: 2019.
Subjects:
Online Access:Link Metadata
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 repouitm_51712
042 |a dc 
100 1 0 |a Muhd Rozi, Muhammad Syafiq  |e author 
700 1 0 |a Md Zain, Noraini  |e author 
245 0 0 |a Higher educational building defects in Perak / Muhammad Syafiq Muhd Rozi and Noraini Md Zain 
260 |c 2019. 
500 |a https://ir.uitm.edu.my/id/eprint/51712/1/51712.pdf 
520 |a Education buildings are prone to building defects and their care is very important to make sure the building is safe to use and maintained. Defects in educational buildings are hazardous to users especially students. For example, education building at Beaufort, Sabah which has defect in the wall structure causing the wall of the building to collapse. Furthermore, this study is about to improve the defect management of the higher educational building in Perak. The objectives of this study is to know the types of defects, the causes of the defects, and to investigates method to overcome the defect in higher educational building. This study uses observation and questionnaires to collect data from the respondents. For objective 1, the result from observation show the common defects found are cracks, dampness, flaking paintwork and plaster, fungus attacks are the most occurring type of defect in educational buildings in Perak. For objective 2 and objective 3, the questionnaires were distributed to 92 targeted respondents which are the maintenance team. In addition, the SPSS version 25 was utilized in analyzing the collected data. Amongst the main reasons that causes defects are age of the building itself. The famous method to overcame the defect is replacing and install new material to recover the defect. 
546 |a en 
690 |a Maintenance and repair 
690 |a Building inspection 
690 |a Building failures, errors, defects, etc. 
690 |a Building fittings and their installation 
690 |a Maintenance and repair 
655 7 |a Conference or Workshop Item  |2 local 
655 7 |a PeerReviewed  |2 local 
787 0 |n https://ir.uitm.edu.my/id/eprint/51712/ 
856 4 1 |u https://ir.uitm.edu.my/id/eprint/51712/  |z Link Metadata