Optimum pH for iron removal in groundwater using powdered activared carbon coagulant / Khairi Khalid, Elias Mohd Den and Mohd Razmi Zainuddin

The objection to high concentrations of iron in groundwater is due to its objectionable colour, taste and odour. Iron is concentrated in water by contact with rocks and minerals and it is understandable that it is usually groundwater supplies that may require treatment for high levels of iron. The o...

Full description

Saved in:
Bibliographic Details
Main Authors: Khalid, Khairi (Author), Mohd Den, Elias (Author), Zainuddin, Mohd Razmi (Author)
Format: Book
Published: 2008.
Subjects:
Online Access:Link Metadata
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 repouitm_68749
042 |a dc 
100 1 0 |a Khalid, Khairi  |e author 
700 1 0 |a Mohd Den, Elias  |e author 
700 1 0 |a Zainuddin, Mohd Razmi  |e author 
245 0 0 |a Optimum pH for iron removal in groundwater using powdered activared carbon coagulant / Khairi Khalid, Elias Mohd Den and Mohd Razmi Zainuddin 
260 |c 2008. 
500 |a https://ir.uitm.edu.my/id/eprint/68749/1/68749.PDF 
520 |a The objection to high concentrations of iron in groundwater is due to its objectionable colour, taste and odour. Iron is concentrated in water by contact with rocks and minerals and it is understandable that it is usually groundwater supplies that may require treatment for high levels of iron. The optimum pH for the removal of iron in ferruginous water was investigated. The investigation involved an analysis of the treatment through carrying out the standard jar test experiment for the determination of residual iron of the supernatant. The experimental results showed that the optimum iron removals were achieved at pH of 5.2 to 8.4 with the optimum pH of 6.34 and the dose of about 25 mg/l with an almost 87.5% removal rate. The concentration of residual iron in treated water by Powdered Activated Carbon (PAC) under optimum coagulant conditions was 0.12 mg/l, which can completely comply with the permissible limit of 0.30 mg/l. The data obtained from this experimental research hopefully is going to provide useful technical information for possible full domestic applications to remove and reduce the undesirable excess iron from any groundwater sources to its acceptable standard permissible limit. 
546 |a en 
690 |a Sources of water supply 
690 |a Groundwater 
655 7 |a Conference or Workshop Item  |2 local 
655 7 |a PeerReviewed  |2 local 
787 0 |n https://ir.uitm.edu.my/id/eprint/68749/ 
856 4 1 |u https://ir.uitm.edu.my/id/eprint/68749/  |z Link Metadata