Diagnostic accuracy between ultrasound and radiography in detecting greenstick fracture with various angulations on pediatric by using homemade distal radius phantom / Nurul Aisyah Mohammad Noor and Lyana Shahirah Mohamad Yamin

The aim of this study is to compare the effectiveness of the ultrasound and radiography in detecting greenstick fracture with different angulations on pediatric by using homemade distal radius phantom. Ten homemade phantoms consist of chicken leg bones and gelatine had been prepared to represent the...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohammad Noor, Nurul Aisyah (Author), Mohamad Yamin, Lyana Shahirah (Author)
Format: Book
Published: 2020.
Subjects:
Online Access:Link Metadata
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 repouitm_69226
042 |a dc 
100 1 0 |a Mohammad Noor, Nurul Aisyah  |e author 
700 1 0 |a Mohamad Yamin, Lyana Shahirah  |e author 
245 0 0 |a Diagnostic accuracy between ultrasound and radiography in detecting greenstick fracture with various angulations on pediatric by using homemade distal radius phantom / Nurul Aisyah Mohammad Noor and Lyana Shahirah Mohamad Yamin 
260 |c 2020. 
500 |a https://ir.uitm.edu.my/id/eprint/69226/2/69226.pdf 
520 |a The aim of this study is to compare the effectiveness of the ultrasound and radiography in detecting greenstick fracture with different angulations on pediatric by using homemade distal radius phantom. Ten homemade phantoms consist of chicken leg bones and gelatine had been prepared to represent the pediatric distal radius. There are two sets of phantoms where each contain two normal chicken leg bones and three chicken leg bones with different angulations of greenstick fracture start with 10°, 20° and 30°. Three emergency physicians were then evaluated all of the phantoms through ultrasound images and radiographic images to obtain diagnostic accuracy results. Based on the result, ultrasound has high specificity (100%) with low sensitivity (55.6%) while the radiography has low specificity (50.0%) and sensitivity (44.4%). From this study, the ultrasound is more effective in detecting greenstick fracture with different angulations on pediatric distal radius by using the phantoms as compared to radiography test. 
546 |a en 
690 |a R Medicine (General) 
690 |a RJ Pediatrics 
690 |a Examination. Diagnosis 
655 7 |a Conference or Workshop Item  |2 local 
655 7 |a PeerReviewed  |2 local 
787 0 |n https://ir.uitm.edu.my/id/eprint/69226/ 
856 4 1 |u https://ir.uitm.edu.my/id/eprint/69226/  |z Link Metadata