Correlational analysis on physical and chemical contaminants of indoor air quality / Amalina Abu Mansor ... [et al.]
The acceptable or good indoor air quality is important in minimizing the risk of getting any building- related illness especially for those staying indoors and working in the health center. This study assessed the IAQ in the health center of a university, involving physical and chemical parameters....
Saved in:
Main Authors: | , , , , , , , |
---|---|
Format: | Book |
Published: |
Faculty of Health Sciences, Universiti Teknologi MARA,
2022-10.
|
Subjects: | |
Online Access: | Link Metadata |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | repouitm_69770 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Abu Mansor, Amalina |e author |
700 | 1 | 0 | |a Radzuan, Nurul Annisah |e author |
700 | 1 | 0 | |a Abdullah, Samsuri |e author |
700 | 1 | 0 | |a Che Dom, Nazri |e author |
700 | 1 | 0 | |a Mohd Yatim, Siti Rohana |e author |
700 | 1 | 0 | |a Mat Jusoh, Suriani |e author |
700 | 1 | 0 | |a Zulkifli, Mohammad Fakhratul Ridwan |e author |
700 | 1 | 0 | |a Ismail, Marzuki |e author |
245 | 0 | 0 | |a Correlational analysis on physical and chemical contaminants of indoor air quality / Amalina Abu Mansor ... [et al.] |
260 | |b Faculty of Health Sciences, Universiti Teknologi MARA, |c 2022-10. | ||
500 | |a https://ir.uitm.edu.my/id/eprint/69770/1/69770.pdf | ||
520 | |a The acceptable or good indoor air quality is important in minimizing the risk of getting any building- related illness especially for those staying indoors and working in the health center. This study assessed the IAQ in the health center of a university, involving physical and chemical parameters. The sampling points are at the entrance door, counter, four treatment rooms, dentist section, and waiting rooms. Sampling was conducted with 15-minutes intervals for each point starting from 0800 hours to 1700 hours for three days. Results show that the respirable suspended particulate (PM 10 ) concentrations (0.015-0.020 mg/m3 ), carbon monoxide (CO) (0.40 - 0.43 ppm), and relative humidity (62.7 -66.9%) comply with standard while temperature (21.9-23.6°C), CO 2 (969-1026 ppm), and air movement (0.01-0.18m/s) did not comply with the standard. Spearmen correlation showed that there was high negative correlation between relative humidity and temperature (r=0.685, p<0.05), CO (r=-0.776, p<0.01) and CO 2 (r=-0.776, p<0.05). Human respiration, diversity of indoor activities, and ventilation system issue are among the important factors in the reduction of IAQ. | ||
546 | |a en | ||
690 | |a Indoor air pollution. Including indoor air quality | ||
690 | |a Chemicals | ||
655 | 7 | |a Article |2 local | |
655 | 7 | |a PeerReviewed |2 local | |
787 | 0 | |n https://ir.uitm.edu.my/id/eprint/69770/ | |
787 | 0 | |n http://healthscopefsk.com/ | |
856 | 4 | 1 | |u https://ir.uitm.edu.my/id/eprint/69770/ |z Link Metadata |