Correlational analysis on physical and chemical contaminants of indoor air quality / Amalina Abu Mansor ... [et al.]

The acceptable or good indoor air quality is important in minimizing the risk of getting any building- related illness especially for those staying indoors and working in the health center. This study assessed the IAQ in the health center of a university, involving physical and chemical parameters....

Full description

Saved in:
Bibliographic Details
Main Authors: Abu Mansor, Amalina (Author), Radzuan, Nurul Annisah (Author), Abdullah, Samsuri (Author), Che Dom, Nazri (Author), Mohd Yatim, Siti Rohana (Author), Mat Jusoh, Suriani (Author), Zulkifli, Mohammad Fakhratul Ridwan (Author), Ismail, Marzuki (Author)
Format: Book
Published: Faculty of Health Sciences, Universiti Teknologi MARA, 2022-10.
Subjects:
Online Access:Link Metadata
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 repouitm_69770
042 |a dc 
100 1 0 |a Abu Mansor, Amalina  |e author 
700 1 0 |a Radzuan, Nurul Annisah  |e author 
700 1 0 |a Abdullah, Samsuri  |e author 
700 1 0 |a Che Dom, Nazri  |e author 
700 1 0 |a Mohd Yatim, Siti Rohana  |e author 
700 1 0 |a Mat Jusoh, Suriani  |e author 
700 1 0 |a Zulkifli, Mohammad Fakhratul Ridwan  |e author 
700 1 0 |a Ismail, Marzuki  |e author 
245 0 0 |a Correlational analysis on physical and chemical contaminants of indoor air quality / Amalina Abu Mansor ... [et al.] 
260 |b Faculty of Health Sciences, Universiti Teknologi MARA,   |c 2022-10. 
500 |a https://ir.uitm.edu.my/id/eprint/69770/1/69770.pdf 
520 |a The acceptable or good indoor air quality is important in minimizing the risk of getting any building- related illness especially for those staying indoors and working in the health center. This study assessed the IAQ in the health center of a university, involving physical and chemical parameters. The sampling points are at the entrance door, counter, four treatment rooms, dentist section, and waiting rooms. Sampling was conducted with 15-minutes intervals for each point starting from 0800 hours to 1700 hours for three days. Results show that the respirable suspended particulate (PM 10 ) concentrations (0.015-0.020 mg/m3 ), carbon monoxide (CO) (0.40 - 0.43 ppm), and relative humidity (62.7 -66.9%) comply with standard while temperature (21.9-23.6°C), CO 2 (969-1026 ppm), and air movement (0.01-0.18m/s) did not comply with the standard. Spearmen correlation showed that there was high negative correlation between relative humidity and temperature (r=0.685, p<0.05), CO (r=-0.776, p<0.01) and CO 2 (r=-0.776, p<0.05). Human respiration, diversity of indoor activities, and ventilation system issue are among the important factors in the reduction of IAQ. 
546 |a en 
690 |a Indoor air pollution. Including indoor air quality 
690 |a Chemicals 
655 7 |a Article  |2 local 
655 7 |a PeerReviewed  |2 local 
787 0 |n https://ir.uitm.edu.my/id/eprint/69770/ 
787 0 |n http://healthscopefsk.com/ 
856 4 1 |u https://ir.uitm.edu.my/id/eprint/69770/  |z Link Metadata