Palm gripper measurement device for post-stroke rehabilitation progressive tracking / Muhammad Najmi Hakim Nasir ... [et al.]

Various devices are used in the medical world to measure grip force. However, there is no well-defined method being used to quantify the distribution of grip forces applied by post-stroke patients. It is important to track the patient's progress in neurofeedback training throughout rehabilitati...

Full description

Saved in:
Bibliographic Details
Main Authors: Nasir, Muhammad Najmi Hakim (Author), Che Zakaria, Noor Ayuni (Author), Othman, Nurul Atiqah (Author), Johar, Khairunnisa (Author), Mohd Mustafah, Nadia (Author), Abd Halim, Azffanizam (Author)
Format: Book
Published: Faculty of Mechanical Engineering Universiti Teknologi MARA (UiTM), 2024-01.
Subjects:
Online Access:Link Metadata
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 repouitm_89544
042 |a dc 
100 1 0 |a Nasir, Muhammad Najmi Hakim  |e author 
700 1 0 |a Che Zakaria, Noor Ayuni  |e author 
700 1 0 |a Othman, Nurul Atiqah  |e author 
700 1 0 |a Johar, Khairunnisa  |e author 
700 1 0 |a Mohd Mustafah, Nadia  |e author 
700 1 0 |a Abd Halim, Azffanizam  |e author 
245 0 0 |a Palm gripper measurement device for post-stroke rehabilitation progressive tracking / Muhammad Najmi Hakim Nasir ... [et al.] 
260 |b Faculty of Mechanical Engineering Universiti Teknologi MARA (UiTM),   |c 2024-01. 
500 |a https://ir.uitm.edu.my/id/eprint/89544/1/89544.pdf 
520 |a Various devices are used in the medical world to measure grip force. However, there is no well-defined method being used to quantify the distribution of grip forces applied by post-stroke patients. It is important to track the patient's progress in neurofeedback training throughout rehabilitation with quantitative evaluation. A palm gripper measurement device is being developed, equipped with Force Sensing Resistors (FSRs) (RP-S40-ST model) to capture grip force. The device provides valuable insights into rehabilitation progress by assessing the grip force. The analogue value from FSRs is linearly interpolated from the input range to the output range using the map function; 'map(avg_force, 0, 1023, 0, 15)' to scale the 'fsrReading' from the input range of 0 to 1023. The input range is converted into a score 0 to 15 scale of a bar graph to indicate the amount of force measured. The accuracy showed by Pearson's r shows a correlation trend between the analogue value and length of the bar graph with 0.97651 and 0.98083, respectively. A matrix was plotted for three subjects with different object sizes for device testing which shows the adjusted R2 is 0.955 highest for big objects and the lowest adjusted R2 is 0.63672 for small objects. 
546 |a en 
690 |a Biomedical engineering 
690 |a Rehabilitation therapy 
655 7 |a Article  |2 local 
655 7 |a PeerReviewed  |2 local 
787 0 |n https://ir.uitm.edu.my/id/eprint/89544/ 
856 4 1 |u https://ir.uitm.edu.my/id/eprint/89544/  |z Link Metadata