Pengaruh Durasi Aplikasi Bahan Adhesif Self-Etch Terhadap Kebocoran Mikro pada Tumpatan Resin Komposit Kelas V

Microleakage was one of the major concerns associated with composite restoration. One of the ways to prevent microleakage was prolonged self-etch adhesive application time. The aim of this study was to evaluate the effect of selfetch adhesive application time on microleakage class V composite restor...

Full description

Saved in:
Bibliographic Details
Main Authors: Hapsari, Rani Indri (Author), , drg. Noor Hafida Widyastuti, Sp.KG (Author), , drg. Nanang Krisnawan (Author)
Format: Book
Published: 2015-03.
Subjects:
Online Access:Connect to this object online
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 repoums_39423
042 |a dc 
100 1 0 |a Hapsari, Rani Indri  |e author 
700 1 0 |a , drg. Noor Hafida Widyastuti, Sp.KG  |e author 
700 1 0 |a , drg. Nanang Krisnawan  |e author 
245 0 0 |a Pengaruh Durasi Aplikasi Bahan Adhesif Self-Etch Terhadap Kebocoran Mikro pada Tumpatan Resin Komposit Kelas V 
260 |c 2015-03. 
500 |a https://eprints.ums.ac.id/39423/9/NASKAH%20PUBLIIKASI.pdf 
500 |a https://eprints.ums.ac.id/39423/1/HALAMAN%20DEPAN.pdf 
500 |a https://eprints.ums.ac.id/39423/2/BAB%20I.pdf 
500 |a https://eprints.ums.ac.id/39423/3/BAB%20II.pdf 
500 |a https://eprints.ums.ac.id/39423/4/BAB%20III.pdf 
500 |a https://eprints.ums.ac.id/39423/5/BAB%20IV.pdf 
500 |a https://eprints.ums.ac.id/39423/6/BAB%20V.pdf 
500 |a https://eprints.ums.ac.id/39423/7/DAFTAR%20PUSTAKA.pdf 
500 |a https://eprints.ums.ac.id/39423/8/LAMPIRAN.pdf 
500 |a https://eprints.ums.ac.id/39423/10/SURAT%20PERNYATAAN%20PUBLIKASI%20KARYA%20ILMIAH.pdf 
520 |a Microleakage was one of the major concerns associated with composite restoration. One of the ways to prevent microleakage was prolonged self-etch adhesive application time. The aim of this study was to evaluate the effect of selfetch adhesive application time on microleakage class V composite restoration. This research was a laboratory experimental study using posttest only control group design. 27 premolar teeth were prepared for class V cavity and were divided into 3 self-etch adhesive application time groups: group I (20 seconds), group 30 (30 seconds), and group III (40 seconds), then cured by light curing and the cavities were restored with composite resin. Specimens were thermocycled, immersed in methylene blue 2% then centrifuged. Teeth were sectioned and evaluated using a stereomicroscope at 120x magnification. Statistical analysis was performed with Kruskal-Wallis (p<0,05) and Mann-Whitney test. The results showed that there was no significant different between group I & II. Significant difference was seen between group II&III and group I&III. Conclusion: self-etch adhesive application time had effect on microleakage class V composite restoration. 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
690 |a RK Dentistry 
655 7 |a Thesis  |2 local 
655 7 |a NonPeerReviewed  |2 local 
787 0 |n https://eprints.ums.ac.id/39423/ 
787 0 |n J520110053 
856 \ \ |u https://eprints.ums.ac.id/39423/  |z Connect to this object online