Keefektifan Poly Aluminium Chloride (Pac) Dalam Menurunkan Kadar Biological Oxygen Demand (Bod) Limbah Cair Rumah Makan

dissolved in water. BOD levels at Fadhila Restaurant in Mencoraya Gonilan Kartasura already exceeded the quality standards thats 716,56 mg/l. According to the Central Java Provincial Regulation No. 5 of 2012 on Domestic Wastewater Quality Standard of 100 mg/l. The purpose of this study to determine...

Full description

Saved in:
Bibliographic Details
Main Author: Galih, Vera Nalurining (Author)
Format: Book
Published: 2016.
Subjects:
Online Access:Connect to this object online
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 repoums_40838
042 |a dc 
100 1 0 |a Galih, Vera Nalurining  |e author 
245 0 0 |a Keefektifan Poly Aluminium Chloride (Pac) Dalam Menurunkan Kadar Biological Oxygen Demand (Bod) Limbah Cair Rumah Makan 
260 |c 2016. 
500 |a https://eprints.ums.ac.id/40838/1/NASKAH%20PUBLIKASI.pdf 
500 |a https://eprints.ums.ac.id/40838/2/HALAMAN%20DEPAN.pdf 
500 |a https://eprints.ums.ac.id/40838/5/BAB%20I.pdf 
500 |a https://eprints.ums.ac.id/40838/6/BAB%20II.pdf 
500 |a https://eprints.ums.ac.id/40838/7/BAB%20III.pdf 
500 |a https://eprints.ums.ac.id/40838/8/BAB%20IV.pdf 
500 |a https://eprints.ums.ac.id/40838/9/BAB%20V.pdf 
500 |a https://eprints.ums.ac.id/40838/10/BAB%20VI.pdf 
500 |a https://eprints.ums.ac.id/40838/11/DAFTAR%20PUSTAKA.pdf 
500 |a https://eprints.ums.ac.id/40838/12/Lampiran.pdf 
500 |a https://eprints.ums.ac.id/40838/19/PERNYATAAN%20PUBLIKASI.pdf 
520 |a dissolved in water. BOD levels at Fadhila Restaurant in Mencoraya Gonilan Kartasura already exceeded the quality standards thats 716,56 mg/l. According to the Central Java Provincial Regulation No. 5 of 2012 on Domestic Wastewater Quality Standard of 100 mg/l. The purpose of this study to determine the effectiveness of poly aluminium chloride (PAC) in lowering levels of effluent BOD restaurant by adding PAC with 250 mg/l, 500 mg/l and 750 mg/l. This research method True Experiment with Pretest and Posttest study design with Control Group. The sampling technique used quota sampling. Statistical tests used of One Way Anova. The results showed difference between the reduction in BOD levels before and after treatment in restaurants wastewater with coagulant PAC (p = 0.000). The most effective dose in lowering levels of BOD in the restaurant wastewater is 500 mg / l with a decrease (80.64%). 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
690 |a R Medicine (General) 
690 |a RA0421 Public health. Hygiene. Preventive Medicine 
655 7 |a Thesis  |2 local 
655 7 |a NonPeerReviewed  |2 local 
787 0 |n https://eprints.ums.ac.id/40838/ 
787 0 |n J410110100 
856 \ \ |u https://eprints.ums.ac.id/40838/  |z Connect to this object online